Skip to main content
Schneider Electric A9N2P40DGN — 2-Pole MCB (DIN Rail)

A9N2P40DGN Acti9 xC60 MCB, 40 A, D Curve, 2P, 10 kA

MPNA9N2P40DGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P40DGN, 40 A rated, D curve, 2 poles, 10 kA breaking capacity, clip-on 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P40DGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P40DGN — Electrical
ParameterValue
Rated current [In]40 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P40DGN — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P40DGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P40DGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P40DGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The A9N2P40DGN is a Schneider Electric Acti9 xC60 miniature circuit breaker — 40 A rated, D curve, 2 poles, with a 10 kA breaking capacity at 240 V and 415 V AC per IS/IEC 60898-1. The thermal-magnetic trip unit handles the overload side; the magnetic coil clears the short-circuit side.

Integration notes

The 36 mm width (4× 9 mm pitches) fits a 2-pole breaker in a compact footprint. Terminals accept up to 35 mm² rigid or 25 mm² flexible; strip 13 mm and torque to 3.5 N·m. IP20 finger-safe front, pollution degree 3 — fine for most industrial control cabinets. The toggle gives ON/OFF indication, and the contact position indicator confirms the state visually.

Frequently asked questions

How do I get pricing and availability for A9N2P40DGN?

Submit an RFQ through this listing. The part is sourced through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9N2P40DGN?

10 kA Icn at both 240 V and 415 V AC, 50/60 Hz, per IS/IEC 60898-1.

What compliance standards does A9N2P40DGN meet?

It complies with IS/IEC 60898-1, and the tropicalisation meets IEC 60068-1 class 2.

MPN
A9N2P40DGN