Skip to main content
Schneider Electric A9N2P63DGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P63DGN Acti9 xC60 MCB, 63 A, D Curve,

MPNA9N2P63DGN
Active

Schneider Electric Acti9 xC60, A9N2P63DGN, miniature circuit breaker, 2P, 63 A, D curve, 10 kA Icn at 415 V AC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N2P63DGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P63DGN — Electrical
ParameterValue
Rated current [In]63 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P63DGN — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P63DGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P63DGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P63DGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P63DGN is an Acti9 xC60 miniature circuit breaker (MCB) rated for 63 A continuous current, with a D tripping curve that triggers magnetic trip between 10 and 14 times the rated current. The 2-pole configuration protects both phase conductors in a single-phase or split-phase distribution circuit. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC, 50/60 Hz, certified to IS/IEC 60898-1. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit — standard MCB architecture, but the D curve's wider magnetic band is what makes this part distinct from the more common C-curve sibling.

Clip-on mounting to a 35 mm DIN rail, 4 module pitches wide (36 mm per pole, so 72 mm total width for the 2P unit). Depth is 77.5 mm, height 85 mm — standard for the Acti9 xC60 family, so it fits existing rail layouts without re-spacing. That matters for panels in coastal plants or unairconditioned enclosures.

Frequently asked questions

Where can I buy A9N2P63DGN and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing — no stock or price figures are published here.

What is the closest alternative to A9N2P63DGN in the Acti9 family?

The closest peer is the C-curve variant of the same 63 A 2P xC60 (order code A9N2P63C). The only difference is the magnetic trip threshold: C curve trips at 5–10 x In, while the D curve trips at 10–14 x In. Choose D for high-inrush loads like motors and transformers; choose C for general-purpose resistive and moderate-inductive circuits. Footprint, terminals, and breaking capacity are identical.

What compliance documentation does this brand provide for A9N2P63DGN?

The MCB is certified to IS/IEC 60898-1. The Acti9 range typically carries CE marking and meets RoHS requirements, though specific documentation (declaration of conformity, RoHS/REACH reports) should be requested at quote time to match your quality-doc control needs.

MPN