Schneider Electric A9N60721 Acti9 C120 MCB, 1P D Curve 100 A

MPNA9N60721
Obsolete

Schneider Electric Acti9 C120 series, A9N60721, miniature circuit-breaker, 1-pole, D curve, 100 A, 5 kA breaking capacity at 400 V AC, thermal-magnetic, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N60721 — Identification
ParameterValue
Product nameActi9 C120
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameC120a
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N60721 — Electrical & Protection
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)230...400 V AC 50/60 Hz
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)5 kA Icu at 230...400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N60721 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1 cable(s) 1...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Width27 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 3.5 N.m top or bottom
A9N60721 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
A9N60721 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2
A9N60721 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

The A9N60721 is a 1-pole Acti9 C120 miniature circuit-breaker rated 100 A at 40 °C with a D tripping curve, meaning its magnetic trip threshold is 12 × In ±20 % — about 1200 A instantaneous — sized for loads with high inrush like motor circuits or transformers where a C curve would nuisance-trip on startup. Breaking capacity is 5 kA Icu at 230…400 V AC 50/60 Hz per EN/IEC 60947-2, which is the standard for distribution boards in commercial and light industrial panels where the prospective fault current stays under that level. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit; D curve gives a wider magnetic band than B or C, so it fits motor feeders, welding equipment, or power supplies with large input capacitors.

Tunnel terminals accept 1…50 mm² rigid or 1.5…35 mm² flexible cable; strip length 15 mm, torque to 3.5 N·m. IP20 finger-safe protection on the front, so it's suitable for open-panel installation inside a locked enclosure.

Frequently asked questions

What is A9N60721's rated current and breaking capacity?

Rated current is 100 A at 40 °C, with a breaking capacity of 5 kA Icu at 230…400 V AC 50/60 Hz per EN/IEC 60947-2.

MPN
A9N60721