Skip to main content
Schneider Electric A9N60721

Schneider Electric A9N60721 Acti9 C120 MCB, 1P D Curve 100 A

MPN A9N60721
Obsolete

Schneider Electric Acti9 C120 series, A9N60721, miniature circuit-breaker, 1-pole, D curve, 100 A, 5 kA breaking capacity at 400 V AC, thermal-magnetic, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N60721 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity5 kA Icu at 230...400 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

A9N60721 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width27 mm
Height81 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The A9N60721 is a 1-pole Acti9 C120 miniature circuit-breaker rated 100 A at 40 °C with a D tripping curve, meaning its magnetic trip threshold is 12 × In ±20 % — about 1200 A instantaneous — sized for loads with high inrush like motor circuits or transformers where a C curve would nuisance-trip on startup. Breaking capacity is 5 kA Icu at 230…400 V AC 50/60 Hz per EN/IEC 60947-2, which is the standard for distribution boards in commercial and light industrial panels where the prospective fault current stays under that level. The thermal-magnetic trip unit combines a bimetal for overload protection and a solenoid for short-circuit; D curve gives a wider magnetic band than B or C, so it fits motor feeders, welding equipment, or power supplies with large input capacitors.

Tunnel terminals accept 1…50 mm² rigid or 1.5…35 mm² flexible cable; strip length 15 mm, torque to 3.5 N·m. IP20 finger-safe protection on the front, so it's suitable for open-panel installation inside a locked enclosure.

MPN
A9N60721