Schneider Electric A9N60754 Acti9 C120N MCB, D Curve, 100 A,

MPNA9N60754
Active

Schneider Electric Acti9 C120N miniature circuit breaker, A9N60754, 3P, D curve, 100 A rated current, 10 kA breaking capacity at 230-400 V AC, clip-on DIN rail mount.

$287.04Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N60754 — Identification
ParameterValue
Product nameActi9 C120
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9N60754 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration3P
Number of protected poles3
Breaking capacity10 kA Icu at 10 kA Icu at 230...400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)7.5 kA 75 % conforming to EN/IEC 60947-2 - 230...400 V AC 50/60 Hz
Rated operational voltage (Ue)230...400 V AC 50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIII
A9N60754 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Limitation class3 conforming to EN/IEC 60947-2
Electrical durability (cycles)5000 cycles
Mechanical durability (cycles)20000 cycles
A9N60754 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Control typeToggle
Terminal connection typeTunnel type terminals1...50 mm² rigid Tunnel type terminals1.5...35 mm² flexible
Terminal tightening torque3.5 N.m
Wire stripping length15 mm
Local signalling/indicationON/OFF indication
Width81 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches9
A9N60754 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9N60754 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The A9N60754 is a Schneider Electric Acti9 C120N miniature circuit breaker — 3-pole, D-curve, rated 100 A at 40 °C. The D curve means magnetic tripping occurs at 10 to 14 times In (12 x In ±20 % here), so it tolerates the high inrush of motor, transformer, or welding loads without nuisance trips. Clip it onto a 35 mm symmetrical DIN rail — that's the standard top-hat rail in every panel. 81 mm wide (9 mm pitch × 9 modules), so it occupies nine 18 mm-wide ways in the enclosure. The IP20 finger-safe terminals mean it's enclosed for panel use, not outdoor or washdown.

Integration notes

Tunnel-type terminals accept 1 to 50 mm² rigid or 1.5 to 35 mm² flexible copper — that's a wide enough range for the 100 A feed. The handle is sealable in OFF or ON position (cable diameter 0.7 mm) for lockout/tagout. Earth-leakage protection requires a separate block — the MCB itself is thermal-magnetic only, no integral RCD.

Designed to EN/IEC 60947-2, limitation class 3 (energy let-through kept low for downstream device protection). Rated insulation voltage 500 V AC. Mechanical durability 20,000 cycles, electrical 5,000 cycles at rated load. The manufacturer provides the usual CE, UKCA, and RoHS declarations with the batch.

Frequently asked questions

Where can I buy A9N60754 and how is it quoted?

We source and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution channels.

What is the breaking capacity of A9N60754?

10 kA Icu at 230-400 V AC 50/60 Hz, conforming to EN/IEC 60947-2. That is the maximum fault current it can safely interrupt.

What is the closest alternative to A9N60754 in the Acti9 family?

Within the Acti9 C120 range, the main variant is the C-curve version (e.g. A9N60753). The D curve here is the choice for high-inrush loads; the C curve is for general distribution. Both share the same 100 A, 3P, 10 kA rating and physical footprint.

MPN
A9N60754