Skip to main content
Schneider Electric A9N60785

Schneider Electric A9N60785 Acti9 C120H MCB, 80 A, 3P, C Cur

MPN A9N60785
Obsolete

Schneider Electric Acti9 C120H miniature circuit-breaker, A9N60785, 3-pole, 80 A, C curve, 15 kA breaking capacity per EN/IEC 60947-2, thermal-magnetic trip, clip-on 35 mm DIN rail.

$214.69 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N60785 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity15 kA Icu at 15 kA Icu at 230...400 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

A9N60785 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width81 mm
Height81 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The A9N60785 is a 3-pole Acti9 C120H miniature circuit-breaker rated 80 A at 40 °C with a C curve (magnetic trip at 8 x In ±20 %). The 15 kA Icu breaking capacity at 230…400 V AC 50/60 Hz per EN/IEC 60947-2 means it can safely interrupt a fault current up to that level without upstream cascading — critical for coordination studies in distribution boards. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit. IP20 finger-safe terminals accept up to 50 mm² rigid or 35 mm² flexible cable with tunnel-type terminals; tightening torque is 3.5 N·m. The 73 mm depth leaves clearance for cover-mounted accessories.

Designed for distribution applications in AC networks at 50/60 Hz. Rated operational voltage 230…400 V AC; rated insulation voltage 500 V AC. Electrical durability 5000 cycles, mechanical durability 20000 cycles. Earth-leakage protection via separate block (not integrated). Local ON/OFF indication on the toggle; handle sealable in OFF or ON position with 0.7 mm cable diameter lock.

MPN
A9N60785