Skip to main content
Schneider Electric A9N61653 — 2-Pole MCB (DIN Rail)

Schneider Electric A9N61653 C60PV-DC MCB, 1 A C-Curve, 2P, 8

MPNA9N61653
Obsolete

Schneider Electric C60PV-DC, miniature circuit-breaker, 1 A, C-curve, 2 poles, 800 V DC, breaking capacity 3 kA at 650 V DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N61653 — Identification
ParameterValue
Product rangeC60
Device short nameC60PV-DC
Product / component typeMiniature circuit-breaker
A9N61653 — Electrical
ParameterValue
Rated current [In]1 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]800 V DC
Network type (AC/DC)DC
A9N61653 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In
Breaking capacity (Icu)3 kA Icu at 650 V DC 1.5 kA Icu at 800 V DC
Rated service breaking capacity [Ics]1.5 kA 100 % - 800 V DC 3 kA 100 % - 650 V DC
Suitable for isolationYes conforming to EN/IEC 60947-2
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N61653 — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height132.7 mm
Depth77.4 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel terminal (downside) 1...25 mm² rigid Tunnel terminal (downside) 1...16 mm² flexible Pre-wired cable (upside)
Terminal tightening torque2.5 N.m
Contact position indicatorYes
A9N61653 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N61653 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The Schneider Electric A9N61653 is a C60PV-DC miniature circuit-breaker, 1 A rated current, C-curve, 2 poles, rated for 800 V DC. It's built for DC photovoltaic strings and small commercial/residential DC distribution — the C-curve magnetic trip at 8.5 x In handles moderate inrush from inverters or DC-DC converters without nuisance trips. The 3 kA Icu at 650 V DC (1.5 kA at 800 V DC) is the fault-clearing ceiling; the service breaking capacity Ics is the same 3 kA at 650 V DC, meaning it can reclose after a fault at that level without derating.

Rated operational voltage 800 V DC. Rated current 1 A.

Rated and marked to EN/IEC 60947-2, utilisation category A (no intentional short-time delay — clears fast). Suitable for isolation per that same standard, so it doubles as a disconnector in the DC circuit. The 1500 cycles electrical durability (L/R = 2 ms) and 20000 cycles mechanical durability give a realistic service life for a PV combiner box that sees only a few operations per year.

Frequently asked questions

What is the breaking capacity of A9N61653?

Breaking capacity is 3 kA Icu at 650 V DC and 1.5 kA Icu at 800 V DC. Service breaking capacity Ics is the same values (100 %), meaning it can reclose after clearing a fault at those levels.

MPN