Schneider Electric A9N61655 — 2-Pole MCB (DIN Rail)

Schneider Electric A9N61655 C60PV-DC MCB, 3 A, C Curve, 2P,

MPNA9N61655
Obsolete

Schneider Electric C60PV-DC miniature circuit breaker, A9N61655, 3 A, C curve, 2 poles, 800 V DC, 3 kA breaking capacity at 650 V DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N61655 — Identification
ParameterValue
Product rangeC60
Device short nameC60PV-DC
Product / component typeMiniature circuit-breaker
A9N61655 — Electrical
ParameterValue
Rated current [In]3 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]800 V DC
Network type (AC/DC)DC
A9N61655 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In
Breaking capacity (Icu)3 kA Icu at 650 V DC 1.5 kA Icu at 800 V DC
Rated service breaking capacity [Ics]1.5 kA 100 % - 800 V DC 3 kA 100 % - 650 V DC
Suitable for isolationYes conforming to EN/IEC 60947-2
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N61655 — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height132.7 mm
Depth77.4 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel terminal (downside) 1...25 mm² rigid Tunnel terminal (downside) 1...16 mm² flexible Pre-wired cable (upside)
Terminal tightening torque2.5 N.m
Contact position indicatorYes
A9N61655 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N61655 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

It is designed for DC circuits in small commercial and residential photovoltaic installations, isolating and protecting against overcurrent and short-circuit faults per EN/IEC 60947-2.

The 3 A rated current (In) sets the continuous load it can carry without tripping; size it for the string current of your PV array or DC load. Breaking capacity is 3 kA Icu at 650 V DC and 1.5 kA Icu at 800 V DC — the maximum fault current it can safely interrupt at those voltages. Service breaking capacity (Ics) is the same values at 100 % of Icu, meaning it can reclose after a fault at full rating without derating. That matters for coordination in a PV combiner box where fault currents can be high. Polarity insensitive — it protects against bi-directional current, which is essential for DC circuits where current can flow either way (e.g., battery banks or PV strings with reverse-current risk). No need to worry about orientation during installation.

Takes up 8 x 9 mm pitches (72 mm wide) on the rail, so plan your DIN rail layout accordingly. Ambient operating range -25…70 °C, storage -40…85 °C, with 95 % RH at 55 °C — fine for outdoor enclosures in most climates.

Frequently asked questions

What is the breaking capacity of A9N61655?

Breaking capacity is 3 kA Icu at 650 V DC and 1.5 kA Icu at 800 V DC. Service breaking capacity (Ics) is the same at 100 % of Icu.

What compliance standards does A9N61655 meet?

It conforms to EN/IEC 60947-2, Category A, and is suitable for isolation per that standard. Polarity insensitive for bidirectional DC protection.

Where can I buy A9N61655 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN
A9N61655