Skip to main content
Schneider Electric A9P42710 — Circuit Breaker Accessories

Schneider Electric A9P42710 Acti9 iC40 MCB, 10A, 3P+N, B-Cur

MPNA9P42710
Obsolete

Schneider Electric Acti9 iC40 miniature circuit breaker, A9P42710, 3P+N, 10 A rated, B-curve, 4.5 kA (Icn) / 6 kA (Icu) breaking capacity, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9P42710 — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 iC40
Product rangeActi9
Device applicationDistribution
A9P42710 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]10 A
Rated operational voltage [Ue]400 V AC 50/60 Hz
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]4 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description3P + N
Magnetic tripping limit3...5 x In conforming to EN/IEC 60898-1 4 x In +/- 20 % conforming to EN/IEC 60947-2
A9P42710 — Protection & Performance
ParameterValue
Breaking capacity4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]4500 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 4.5 kA 75 % x Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingON/OFF indication Trip indicator
Contact position indicatorYes
A9P42710 — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid
Device short nameiC40
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height85 mm
Depth74 mm
ColourWhite
A9P42710 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
A9P42710 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2
A9P42710 — Specifications
ParameterValue
Curve codeB
Number of protected poles3

Product details

The Schneider Electric A9P42710 is an Acti9 iC40 miniature circuit breaker (MCB) — a 3P+N, 10 A rated device with a B-curve trip characteristic, used for branch-circuit protection in distribution panels.

Breaking capacity is dual-rated: 4.5 kA Icn per EN/IEC 60898-1 (the MCB standard for household and similar installations) and 6 kA Icu per EN/IEC 60947-2 (the industrial standard for switchgear). The 3P+N configuration protects three phases; the neutral pole is switched but not protected (no overcurrent trip on N). Isolation capability is confirmed per EN/IEC 60947-2 — you can use this MCB as a disconnection point for the downstream circuit during maintenance.

Clip-on mounting to a standard 35 mm DIN rail, with tunnel-type terminals accepting 1–16 mm² rigid or 1–10 mm² flexible wire. The neutral position is left, which matches the typical busbar arrangement in Acti9 distribution boards.

Frequently asked questions

Where can I buy the A9P42710 and get a price?

The A9P42710 is sourced to order against an RFQ through independent distribution channels. Submit a request for quote to confirm current availability and pricing.

What is the breaking capacity of the A9P42710?

The A9P42710 has a dual breaking capacity: 4.5 kA Icn per EN/IEC 60898-1 and 6 kA Icu per EN/IEC 60947-2, both at 400 V AC 50/60 Hz.

What standards does the A9P42710 comply with?

It complies with EN/IEC 60898-1 (miniature circuit-breaker standard) and EN/IEC 60947-2 (low-voltage switchgear standard), with IMQ quality label and suitability for isolation per EN/IEC 60947-2.

MPN
A9P42710