Skip to main content
Schneider Electric A9P42720

Schneider Electric A9P42720 Acti9 iC40 MCB, Curve B, 20 A, 3

MPN A9P42720
Obsolete

Schneider Electric Acti9 iC40 miniature circuit breaker, A9P42720, Curve B, 20 A, 3P+N, breaking capacity 4.5 kA Icn / 6 kA Icu, DIN-rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P42720 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P42720 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this MCB covers

The Schneider Electric A9P42720 is an Acti9 iC40 miniature circuit breaker rated 20 A, 3P+N, with a B tripping curve. The B curve trips magnetically at 3 to 5 times In (3...5 x In per EN/IEC 60898-1, 4 x In +/- 20 % per EN/IEC 60947-2), so it clears a short-circuit fast enough to avoid nuisance trips on moderate inrush, yet it still holds on normal starting current of a resistive load. Breaking capacity is 4.5 kA Icn at 400 V AC (EN/IEC 60898-1) and 6 kA Icu at 400 V AC (EN/IEC 60947-2). That dual rating means it qualifies for both domestic-standard (60898) and industrial-standard (60947) installations — the higher Icu figure is the ultimate breaking capacity under the industrial standard, which is what a panel designer checks for fault-withstand coordination upstream.

Height 85 mm, depth 74 mm. Terminal tunnels accept 1…16 mm² rigid or 1…10 mm² flexible, stripped 14 mm, torqued to 2 N·m. Neutral is on the left (fixed position). IP20 on the body, IP40 inside a modular enclosure — fine for a clean distribution board, not for washdown zones.

MPN