Skip to main content
Schneider Electric A9P42740

Schneider Electric A9P42740 Acti9 iC40 MCB, 40A B-Curve 3P+N

MPN A9P42740
Obsolete

Schneider Electric Acti9 iC40, A9P42740, miniature circuit breaker, 40 A, B curve, 3P+N, 4.5 kA Icn / 6 kA Icu, DIN-rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P42740 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P42740 additional specifications
ParameterValue
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P42740 is an Acti9 iC40 miniature circuit breaker (MCB) rated at 40 A with a B-curve trip characteristic, 3P+N poles, and a breaking capacity of 4500 A Icn at 400 V AC per EN/IEC 60898-1 and 6 kA Icu at 400 V AC per EN/IEC 60947-2.

The 40 A rated current (In) sets the continuous load this breaker can carry without tripping — sized for a 40 A distribution circuit feeding sub-panels, large fixed loads, or feeder protection. The 4.5 kA Icn (service breaking capacity per 60898-1) tells you the breaker can safely interrupt a fault up to 4.5 kA repeatedly — adequate for most domestic or light commercial distribution boards. The 6 kA Icu (ultimate breaking capacity per 60947-2) is the one-shot fault limit; if your available fault current exceeds 6 kA at the panel, you need a higher-rated breaker upstream or a current-limiting device. The 3P+N configuration protects three live poles with a switched neutral (left-side neutral position). The neutral pole is not protected — it switches but does not trip. The IP20 finger-safe terminals and IP40 modular enclosure mean it's suited for enclosed distribution boards, not washdown environments.

The 54 mm width (6 x 9 mm pitches) and 85 mm height fit standard modular enclosure grids. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible wire; strip 14 mm and torque to 2 N·m. The toggle handle provides ON/OFF and trip indication — useful for quick visual status checks on the panel door.

MPN