Skip to main content
Schneider Electric A9P52602 — 1-Pole MCB (DIN Rail)

Schneider Electric A9P52602 Acti9 iC40 MCB, 2 A, Curve C, 1P

MPNA9P52602
Active

Schneider Electric Acti9 iC40, miniature circuit-breaker, A9P52602, 2 A, curve C, 1P+N, 6 kA Icu at 230 V AC, DIN rail clip-on.

$48.33Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9P52602 — Identification
ParameterValue
Product nameActi9 iC40
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiC40
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9P52602 — Electrical & Protection
ParameterValue
Rated current (In)2 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In conforming to EN/IEC 60898-1 8 x In +/- 20 % conforming to EN/IEC 60947-2
Breaking capacity (Icu / AIR)6 kA Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9P52602 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth74 mm
Tightening torque (by circuit)2 N.m top or bottom
A9P52602 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
A9P52602 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1 EN/IEC 60947-2
A9P52602 — Electrical
ParameterValue
[Ui] rated insulation voltage400 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-2

Product details

What this 2 A MCB does on the panel

The Schneider Electric A9P52602 is an Acti9 iC40 miniature circuit-breaker rated 2 A, curve C, 1P+N — so it protects a single-phase AC branch at 2 A with a magnetic trip between 5 and 10 times In (10 A to 20 A). Breaking capacity is 6 kA Icu at 230 V AC per IEC 60947-2, and 4500 A Icn per IEC 60898-1 — enough for most residential and light commercial distribution boards.

Dual-rated to EN/IEC 60898-1 (for household-type MCB performance) and EN/IEC 60947-2 (for industrial circuit-breaker application). Limitation class 3 per 60898-1 means it limits let-through energy well. Pollution degree 3 per 60947-2 suits it for conventional factory-floor environments. IP20 on the terminals, IP40 on the modular enclosure. IMQ quality label.

Termination and environment

Thermal-magnetic trip unit, 20000 electrical and 20000 mechanical cycles. Earth-leakage protection requires a separate block — not integrated.

Frequently asked questions

Where can I buy A9P52602?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9P52602?

6 kA Icu at 230 V AC per EN/IEC 60947-2, and 4500 A Icn at 230 V AC per EN/IEC 60898-1.

What compliance documentation is available for A9P52602?

The MCB carries IMQ quality label and is certified to EN/IEC 60898-1 and EN/IEC 60947-2. RoHS and REACH compliance documentation is typically provided by Schneider Electric upon request.

MPN