Skip to main content
Schneider Electric A9P52616

Schneider Electric A9P52616 Acti9 iC40 MCB, 16 A, C Curve, 6

MPN A9P52616
Active

Schneider Electric Acti9 iC40 miniature circuit-breaker, A9P52616, 1P+N, 16 A, C curve, 6 kA Icu at 230 V AC, clip-on DIN rail, white.

$39.04 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P52616 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P52616 additional specifications
ParameterValue
Depth74 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P52616 is an Acti9 iC40 miniature circuit-breaker rated 16 A with a C curve, in a 1P+N pole configuration. It carries a 6 kA Icu breaking capacity at 230 V AC per IEC 60947-2 and 4500 A Icn per IEC 60898-1, so it handles both residential and light commercial fault levels within a single DIN-rail footprint.

Breaking capacity and dual standard

Rated 6 kA Icu (ultimate breaking capacity) under IEC 60947-2 and 4500 A Icn under IEC 60898-1. The 4500 A Icn figure applies to residential distribution boards where the standard expects a lower prospective fault current.

C curve and trip characteristics

C curve means magnetic tripping occurs between 5 and 10 times In (80 to 160 A for this 16 A unit) per IEC 60898-1, with a tighter 8 x In ±20 % tolerance per IEC 60947-2. That suits mixed loads with moderate inrush — lighting banks, small motor starters, and general-purpose socket circuits. The thermal-magnetic trip unit provides overload protection via the bimetal element and short-circuit protection via the solenoid.

Physical integration and environment

Clip-on mounting to DIN rail, 18 mm width (2 x 9 mm pitches), 74 mm depth, 85 mm height. The tunnel terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable, with a 14 mm strip length and 2 N·m tightening torque.

Listed as current production (active lifecycle stage). No successor or end-of-life notice on record.

MPN