Skip to main content
Schneider Electric A9P52716

Schneider Electric A9P52716 Acti9 iC40 MCB, 16 A, 3P+N, C-Cu

MPN A9P52716
Active

Schneider Electric Acti9 iC40 miniature circuit breaker, A9P52716, 16 A, 3P+N, C-curve, 4.5 kA Icn / 6 kA Icu at 400 V AC, DIN rail clip-on.

$82.94 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P52716 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P52716 additional specifications
ParameterValue
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P52716 is an Acti9 iC40 miniature circuit breaker — a thermal-magnetic MCB rated for 16 A with a C-curve trip characteristic, in a 3P+N pole configuration. The 54 mm width (6 x 9 mm pitches) fits a standard modular enclosure slot.

This breaker carries dual breaking-capacity ratings: 4.5 kA Icn per EN/IEC 60898-1 and 6 kA Icu per EN/IEC 60947-2, both at 400 V AC. The Icn figure governs its use as a domestic/residential MCB under the 60898 standard; the higher Icu rating means it also qualifies as an industrial circuit breaker under 60947-2, so it can be specified in commercial or light-industrial distribution boards where fault current may reach 6 kA.

DIN-rail integration and panel wiring

Clip-on mounting on a standard DIN rail, neutral on the left side. Terminals are tunnel type — accepts 1–16 mm² rigid or 1–10 mm² flexible copper, with a 2 N·m tightening torque and 14 mm strip length. The toggle gives ON/OFF plus a trip-indicator flag; the contact-position indicator confirms isolation status per EN/IEC 60947-2.

Complies with EN/IEC 60898-1 and EN/IEC 60947-2, carries IMQ quality label, and is rated for isolation duty. Earth-leakage protection requires a separate block — not integrated.

MPN