Skip to main content
Schneider Electric A9P54706

Schneider Electric A9P54706 Acti9 iC40N MCB, C-Curve 6 A 3P+

MPN A9P54706
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, A9P54706, 6 A rated, C-curve, 3P+N, 10 kA Icu at 400 V AC, clip-on DIN rail mount.

$137.81 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P54706 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P54706 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P54706 is an Acti9 iC40N miniature circuit breaker rated 6 A with a C-curve, meaning its magnetic trip operates between 5 and 10 times the rated current (5–10 x In per EN/IEC 60898-1, and 8 x In ±20 % per EN/IEC 60947-2). The 3P + N configuration protects three phases and switches the neutral, with the neutral pole on the left side of the unit. Breaking capacity is rated at 10 kA Icu at 400 V AC per EN/IEC 60947-2 (industrial standard) and 6000 A Icn at 400 V AC per EN/IEC 60898-1 (domestic/commercial standard). The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit response. Rated for 20000 electrical and 20000 mechanical cycles, it matches the endurance expected for a distribution MCB in a panel that sees regular switching.

Where it goes — panel integration

The 54 mm width occupies 6 x 9 mm pitches, fitting a standard 6-module position in a consumer unit or distribution board. Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible conductors; tightening torque is 2 N.m. IP20 rated on the front (finger-safe), IP40 inside the modular enclosure — suitable for dry indoor panels, not washdown environments. The toggle control provides ON/OFF indication plus a separate trip indicator, so a tripped breaker is visually distinct from one manually switched off. Earth-leakage protection requires a separate Vigi block — this MCB alone does not include RCD functionality.

Approvals include IMQ quality label and compliance with EN/IEC 60898-1 and EN/IEC 60947-2. The dual-standard certification means the breaker carries both the domestic/commercial MCB standard and the industrial circuit-breaker standard, simplifying specification across different installation types.

MPN
A9P54706