Specifications

A9P64306 — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 iC40
Product rangeActi9
Device applicationDistribution
A9P64306 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]6 A
Rated operational voltage [Ue]400 V AC 50/60 Hz
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]4 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description3P
Magnetic tripping limit10...14 x In conforming to EN/IEC 60898-1 12 x In +/- 20 % conforming to EN/IEC 60947-2
A9P64306 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingON/OFF indication Trip indicator
Contact position indicatorYes
A9P64306 — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid
Device short nameiC40N
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height85 mm
Depth74 mm
ColourWhite
A9P64306 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
A9P64306 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2
A9P64306 — Specifications
ParameterValue
Curve codeD
Number of protected poles3

Product details

The Schneider Electric A9P64306 is a 3-pole Acti9 iC40N miniature circuit breaker rated at 6 A with a D tripping curve. The D-curve magnetic trip operates at 10–14 × In (per EN/IEC 60898-1) or 12 × In ±20 % (per EN/IEC 60947-2), which means it tolerates the high inrush of motor or transformer loads without nuisance tripping — the right choice when the load draws a short-duration surge well above running current.

Breaking capacity and dual-standard rating

This breaker carries two breaking-capacity figures: 10 kA Icu at 400 V AC per EN/IEC 60947-2 (the industrial standard for isolation and fault clearing) and 6000 A Icn at 400 V AC per EN/IEC 60898-1 (the residential / commercial standard). The 10 kA figure governs its use in industrial panels where fault current may be higher; the 6 kA rating satisfies domestic distribution board requirements.

Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible copper; strip length 14 mm, tighten to 2 N·m. IP20 finger-safe on the front, IP40 inside a modular enclosure.

Frequently asked questions

Where can I buy A9P64306?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9P64306?

10 kA Icu at 400 V AC per EN/IEC 60947-2, and 6000 A Icn at 400 V AC per EN/IEC 60898-1.

What compliance documentation does Schneider provide for A9P64306?

The breaker carries AENOR quality label and is certified to EN/IEC 60898-1 and EN/IEC 60947-2. Pollution degree 3 per the latter standard.

MPN
A9P64306