Skip to main content
Schneider Electric A9P64716 — Circuit Breaker Accessories

Schneider Electric A9P64716 Acti9 iC40N MCB, 16 A, D Curve,

MPNA9P64716
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, A9P64716, 3P+N, 16 A rated current, D curve, 10 kA Icu at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9P64716 — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 iC40
Product rangeActi9
Device applicationDistribution
A9P64716 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]16 A
Rated operational voltage [Ue]400 V AC 50/60 Hz
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]4 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description3P + N
Magnetic tripping limit10...14 x In conforming to EN/IEC 60898-1 12 x In +/- 20 % conforming to EN/IEC 60947-2
A9P64716 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingON/OFF indication Trip indicator
Contact position indicatorYes
A9P64716 — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid
Device short nameiC40N
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height85 mm
Depth74 mm
ColourWhite
A9P64716 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
A9P64716 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2
A9P64716 — Specifications
ParameterValue
Curve codeD
Number of protected poles3

Product details

The Schneider Electric A9P64716 is a 3P+N miniature circuit breaker from the Acti9 iC40N series, rated 16 A with a D tripping curve. The D curve means the magnetic trip operates at 10 to 14 times In (per EN/IEC 60898-1) or 12 x In ±20 % (per EN/IEC 60947-2) — that wide instantaneous threshold is sized for high-inrush loads like motor starters, transformers, and discharge lighting where the start-up surge would nuisance-trip a B or C curve breaker. The thermal-magnetic trip unit handles the overload protection; the magnetic element clears short-circuits.

This breaker carries a dual-rated breaking capacity: 10 kA Icu at 400 V AC per EN/IEC 60947-2 (the industrial standard for performance) and 6000 A Icn at 400 V AC per EN/IEC 60898-1 (the household/ commercial standard). The 6 kA Icn rating is the lower commercial-duty value; the breaker is certified to both standards, so it fits installations that require either. It is also approved for isolation (suitability for isolation per EN/IEC 60947-2) — meaning it doubles as a visible-break disconnect when locked off with a padlocking device.

The 3P+N body takes 6 x 9 mm pitches — 54 mm wide total — so it occupies three standard module spaces plus a neutral pole. Tunnel terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible; tightening torque is 2 N.m top or bottom. IP20 on the terminals, IP40 inside a modular enclosure — fine for a clean panel, not for washdown zones.

Frequently asked questions

What is the breaking capacity of A9P64716?

The A9P64716 has a breaking capacity of 10 kA Icu at 400 V AC per EN/IEC 60947-2 and 6000 A Icn at 400 V AC per EN/IEC 60898-1.

Where can I buy A9P64716?

The A9P64716 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance standards does A9P64716 meet?

The A9P64716 complies with EN/IEC 60898-1 and EN/IEC 60947-2, and carries quality labels AENOR and OVE.

MPN