Skip to main content
Schneider Electric A9Q04240

Schneider Electric A9Q04240 Vigi iC60 Add-on RCD, 2P, 40 A,

MPN A9Q04240
Active

Schneider Electric Acti9 Vigi iC60, add-on residual current device, A9Q04240, 2P, 40 A, 300 mA, AC type, instantaneous, 130 VAC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Q04240 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage130 V AC 50/60 Hz conforming to EN/IEC 61009-1 130 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width36 mm
Height91 mm
Operating temperature-5...60 °C

Product details

The Schneider Electric A9Q04240 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to plug directly onto the busbar side of a compatible iC60 miniature circuit breaker (MCB) to add earth-leakage protection in a single-width module. Rated 40 A and 300 mA sensitivity, AC type, instantaneous — so it trips on sinusoidal AC fault currents with no intentional delay. The 300 mA threshold suits sub-main or feeder circuits where a 30 mA RCD would nuisance-trip on cumulative leakage (multiple loads, long cable runs). Voltage-independent tripping means the solenoid operates from the fault current itself, not from a powered electronic circuit — it still clears a ground fault even if the phase voltage is lost.

Clip-on to a 35 mm DIN rail, 2-pole width (36 mm, 4 x 9 mm pitches). Plugs directly onto the bottom of an iC60 MCB — no additional wiring between breaker and RCD. Designed as an outgoer device in the final distribution board. IP20 on the front face; IP40 inside the modular enclosure when all blanking plates are fitted. Bottom tunnel terminals accept 1 to 35 mm² rigid cable (or 1 to 25 mm² flexible with/without ferrule). Comb-busbar compatible on the bottom side.

Designed and certified to EN/IEC 61009-1 and EN/IEC 61009-2-1 (RCDs for household and similar uses). Rated insulation voltage 500 V AC; rated impulse withstand voltage 6 kV per IEC 60947-2. 8/20 µs impulse withstand tested at 250 A per IEC 61009-1 — meaning it survives surge events common in industrial mains without nuisance tripping or damage.

MPN
A9Q04240