Schneider Electric A9Q16225

A9Q16225 Acti9 Vigi iC60 RCD, 2P 25A AC Type 500mA

MPN A9Q16225
Obsolete

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 25 A, AC type, 500 mA, instantaneous, 230…415 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Q16225 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width27 mm
Height91 mm
Operating temperature-5...60 °C

Product details

The A9Q16225 is an add-on residual current device (RCD) from the Schneider Electric Acti9 Vigi iC60 range, designed to plug into a compatible Acti9 iC60 MCB to provide earth leakage protection in a single module width. It is a 2-pole unit rated at 25 A, with a 500 mA sensitivity and AC-type (sinusoidal) earth leakage detection.

The 500 mA sensitivity is an instantaneous trip — no intentional time delay. That means it clears a ground fault as soon as the residual current exceeds the threshold, which is typical for general-purpose socket-outlet or final-circuit protection where selectivity with upstream RCDs is not required. The AC-type detection covers sinusoidal AC residual currents only; if the circuit includes non-linear loads like VFDs, LED drivers, or switched-mode power supplies that can generate pulsed DC or high-frequency leakage, an A-type or B-type RCD would be needed instead. Rated operational voltage is 230…415 V AC 50/60 Hz, which covers single-phase (L-N) and two-phase (L-L) circuits within a 2-pole configuration. The IP20 / IP40 (modular enclosure) rating means it is protected against solid objects larger than 12 mm (IP20) and, once installed in a modular enclosure, against objects larger than 1 mm (IP40).

The device occupies 3 x 9 mm pitches, or 27 mm width. The plug-in connection to the MCB means the RCD shares the same busbar and load terminals as the iC60 breaker — no separate wiring for the phase and neutral through the RCD. Bottom terminals are tunnel type, accepting 1…25 mm² rigid or 1…16 mm² flexible conductors, with a tightening torque of 2 N·m. Wire stripping length for the bottom connection is 14 mm.