Specifications

A9Q16325 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)500 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9Q16325 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9Q16325 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9Q16325 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules6
Terminal connectionsTunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end
Wire stripping length14 mm for bottom connection
Terminal tightening torque2 N.m bottom
Width54 mm
Height91 mm
Depth73.5 mm
A9Q16325 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9Q16325 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Schneider Electric A9Q16325 is a 3-pole add-on residual current device (RCD) from the Acti9 Vigi iC60 range, rated 25 A with 500 mA earth-leakage sensitivity, Type AC. It clips onto the side of an iC60 MCB via the plug-in electrical connection, converting that outgoing circuit into an RCBO assembly. The 73.5 mm depth and 54 mm width keep the combined unit within a standard DIN-rail pitch of 6 modules (9 mm each).

The 500 mA sensitivity is a delayed-action or high-threshold trip — it is not for personnel protection (which requires 30 mA or lower). This block is sized for equipment protection or fire-prevention on circuits where nuisance tripping from leakage in long cable runs or industrial loads would otherwise be a problem. The insulation voltage is rated 500 V AC, and impulse withstand is 6 kV, both per IEC 60947-2. The residual current tripping technology is voltage-independent — it does not need an external power supply to operate. If the line voltage drops or is lost, the RCD still trips on a ground fault. The trip is instantaneous with no intentional time delay.

Deployment context

Mounts via clip-on onto a DIN rail, side-coupled to an iC60 MCB. The IP20 rating (IP40 in a modular enclosure) suits dry indoor panel environments — not washdown or outdoor use.

Frequently asked questions

Where can I buy A9Q16325 and how do I get a price?

The A9Q16325 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is A9Q16325's listed depth?

The A9Q16325 has a depth of 73.5 mm.

What is A9Q16325's listed range?

The A9Q16325 belongs to the Acti9 range.

What compliance documentation does this brand provide for A9Q16325?

The A9Q16325 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. The manufacturer typically provides RoHS and REACH declarations upon request.

MPN
A9Q16325