Schneider Electric A9Q16340 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Q16340 Vigi iC60, 40A, 500mA, AC type R

MPNA9Q16340
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9Q16340, 3P, 40 A, 500 mA, Type AC, obsolete, sourced to order.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Q16340 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)500 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9Q16340 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9Q16340 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9Q16340 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end
Wire stripping length14 mm for bottom connection
Terminal tightening torque3.5 N.m bottom
Width63 mm
Height91 mm
Depth73.5 mm
A9Q16340 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9Q16340 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

Product identity and lifecycle

The Schneider Electric A9Q16340 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed for AC networks at 50/60 Hz. It is a 3-pole unit rated at 40 A with a 500 mA earth-leakage sensitivity, Type AC (sinusoidal AC residual currents only). The manufacturer lists this part as obsolete.

Rated operational voltage is 230…415 V AC, covering standard single-phase and three-phase supplies. The 500 mA sensitivity is instantaneous — no intentional time delay — so it trips without added lag on a ground fault. This is a voltage-independent RCD: the tripping mechanism does not rely on the line voltage to operate, which means it remains functional even if the neutral is lost upstream. The 6 kV rated impulse withstand voltage (Uimp) per IEC 60947-2 indicates it can handle typical surge events without damage.

Clip-on mounting onto DIN rail, 7 module pitches wide (9 mm per pitch = 63 mm width). Depth is 73.5 mm, height 91 mm. The unit plugs into the downstream side of a compatible Acti9 iC60 MCB via the integrated plug-in electrical connection — no additional wiring between the MCB and RCD. Stripping length 14 mm. IP20 finger-safe protection; IP40 inside a modular enclosure.

Pollution degree 3 per IEC 60947-2. Storage temperature range -40…85 °C; operating range -5…60 °C. The 8/20 µs impulse withstand of 250 A per IEC 61009-1 covers common surge shapes. Documentation for RoHS, REACH, and UL compliance should be requested at quote time — the spec record does not list those certifications explicitly.

Frequently asked questions