Skip to main content
Schneider Electric A9Q31340

A9Q31340 Acti9 Vigi iC60 3P 40A 30mA A-SI RCD, obsolete

MPN A9Q31340
Active

Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 40 A, 30 mA, Type A-SI, instantaneous, 400…415 V AC, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Q31340 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width63 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Q31340 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range — a voltage-independent, instantaneous-trip module that plugs into the side of an iC60 MCB to add earth-leakage protection. It is rated 40 A, 30 mA sensitivity, Type A-SI (Super Immunised), meaning it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics common on VFD-fed or UPS-backed circuits. Three-pole (3P) construction clips onto DIN rail, occupying 7 modules of 9 mm pitch (63 mm wide).

Lifecycle reality — obsolete, but available

The A9Q31340 is marked obsolete by Schneider Electric. If you are holding a last-time-buy window or managing a legacy panel, this is the part to source now; there is no direct drop-in replacement from the manufacturer.

Rated operational voltage is 400…415 V AC, 50/60 Hz, per EN/IEC 61009-1 and -2-1 — the standard for residual-current-operated circuit-breakers with integral overcurrent protection. Type A-SI (Super Immunised) means it withstands 8/20 µs impulse currents up to 3000 A without tripping, so it holds steady on circuits with surge suppressors or switching transients. Instantaneous trip time means no intentional delay — it clears a ground fault as fast as the coil can move.

Clip-on mounting to DIN rail, 63 mm wide (7 x 9 mm pitches). Depth is 73.5 mm, height 91 mm. IP20 on the body, IP40 inside a modular enclosure. Bottom comb busbar compatible. The trip indicator gives local visual confirmation of a residual-current event — useful for panel troubleshooting.

MPN
A9Q31340