Schneider Electric A9Q61340

Schneider Electric A9Q61340 Acti9 Vigi iC60, 40A, 30mA, 3P

MPN A9Q61340
Active

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 3P, 40A, 30 mA, Type A-SI (Super Immunised), instantaneous, 400...415 V AC, 50/60 Hz.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Q61340 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width63 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Q61340 is a 3-pole add-on residual current device (RCD) from the Acti9 Vigi iC60 series, rated 40 A with 30 mA earth-leakage sensitivity. It clips onto the side of an Acti9 iC60 miniature circuit breaker (MCB) via the plug-in electrical connection, making it a combined RCBO assembly in a single DIN-rail footprint. The 63 mm width and 73.5 mm depth fit standard 9 mm pitch enclosures — it occupies 7 pitches. This is an outgoer device, meaning it sits downstream of the main breaker to protect a specific final circuit.

Why the Type A-SI and 30 mA matter

The Type A-SI (Super Immunised) earth-leakage protection is voltage-independent — it trips on residual current alone, without needing a separate power supply. The "SI" suffix means it's hardened against nuisance tripping from high-frequency leakage and transient surges common on drives, inverters, and switching power supplies. In a mill environment with VFDs and contactor coils, standard Type A RCDs can false-trip on the capacitive leakage from drive input filters; the A-SI holds through that. The 30 mA sensitivity catches direct-contact faults (hand-to-ground currents above the let-go threshold) while the instantaneous time delay clears the fault in under 40 ms — no intentional delay for selectivity. The 8/20 µs impulse withstand of 3000 A means it survives lightning-induced or switching surges without damage.

Mounting is clip-on to a DIN rail, with the plug-in connection to the adjacent iC60 MCB. The tunnel-type terminals on the bottom accept 1 to 35 mm² rigid cable (or 1 to 25 mm² flexible, with or without ferrule). The bottom busbar and distribution block compatibility means you can feed the line side via a comb busbar across multiple devices. The IP20 rating covers the device body; in a modular enclosure it reaches IP40 — sufficient for enclosed distribution boards but not for washdown locations.