Schneider Electric A9R01491 — Residual Current Breakers (RCCB/RCBO)

Schneider A9R01491 Acti9 iID RCCB, 100 A, 30 mA, 4P

MPNA9R01491
Active

Schneider Electric Acti9 iID, A9R01491, 4-pole RCCB, 100 A rated, 30 mA Type A sensitivity, 380-415 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R01491 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R01491 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R01491 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R01491 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R01491 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R01491 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

It carries a 100 A rated current (In) and a 30 mA earth-leakage sensitivity. Voltage-independent tripping (no auxiliary supply needed) means it will still open on a lost neutral or a phase-to-earth fault even if the upstream voltage collapses. Insulation voltage is 500 V, and impulse withstand is 6 kV.

Neutral is on the left. The 73.5 mm depth leaves room in a standard 100 mm deep enclosure for wiring and a padlocking device. Terminals accept 1…35 mm² rigid or 1…25 mm² flexible (with or without ferrule); strip length is 14 mm, torque to 3.5 N.m.

Frequently asked questions

What is the closest pin-compatible alternative to A9R01491 in this component family?

Within the Acti9 iID family, the closest alternative would share the same 4-pole, 100 A, 30 mA Type A specification but may differ in width (9 mm pitch count) or terminal arrangement. Verify the specific order code against your panel layout before substituting.

MPN
A9R01491