Skip to main content
Schneider Electric A9R04291 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R04291 Acti9 iID RCCB, 100A, 300mA, 2P

MPNA9R04291
Obsolete

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 100 A, 300 mA sensitivity, Type A, 220-240 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R04291 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R04291 — Electrical Ratings
ParameterValue
Rated current (In)100 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R04291 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R04291 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73.5 mm
A9R04291 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R04291 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R04291 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, 100 A unit with 300 mA earth-leakage sensitivity, Type A protection, rated for 220-240 V AC 50/60 Hz networks. The 300 mA sensitivity is the key fit check: this is a fire-protection or equipment-protection device, not a personnel-protection RCCB (those are 30 mA). For a submain feeding a workshop or a machine group where nuisance tripping on a 30 mA unit would be a problem, the 300 mA A9R04291 is the standard choice.

Rated breaking capacity and coordination

Rated breaking and making capacity is 1500 A (Idm and Im both 1500 A). The 1500 A figure is typical for this class of RCCB; it's not a standalone SCCR. Rated impulse withstand voltage is 6 kV (Uimp), and insulation voltage is 500 V AC.

Installation and wiring

Clip-on DIN rail mount, neutral on the left. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable, with a stripping length of 14 mm and a tightening torque of 3.5 N.m. That's a solid connection range for a 100 A device — 35 mm² is roughly the right conductor size for 100 A in PVC cable. IP20 on the terminals (finger-safe), IP40 inside a modular enclosure.

Frequently asked questions

What compliance documentation does this brand provide for A9R04291?

The A9R04291 is designed to EN/IEC 61008-1 standards. Specific RoHS, REACH, and UL documentation should be confirmed at time of order.

MPN