Schneider Electric A9R04440

Schneider Electric A9R04440 Acti9 iID RCCB, 4P, 40 A, 300 mA

MPN A9R04440
Active

Schneider Electric Acti9 iID, RCCB, 4P, 40 A, 300 mA sensitivity, Type A, voltage-independent, EN/IEC 61008-1, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R04440 specifications
ParameterValue
Control typeToggle
Voltage380...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width72 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9R04440 is an Acti9 iID residual current circuit breaker (RCCB) — 4 poles, rated 40 A, with 300 mA earth-leakage sensitivity, Type A, voltage-independent tripping. The 73.5 mm depth and 72 mm width mean it occupies a standard 4-module slot in an Acti9 enclosure.

The 40 A rated current (In) and 300 mA sensitivity are the two numbers that decide whether this RCCB fits your circuit. 40 A is the continuous load it can carry — sized for a submain or feeder feeding multiple branch circuits, not a single appliance. Type A detection catches pulsating DC residual currents (half-wave rectified) plus sinusoidal AC — common on circuits with electronic loads. Voltage-independent tripping means the RCCB disconnects even if the supply neutral is lost; it stores its own trip energy from the fault current. Rated operational voltage is 380...415 V AC 50/60 Hz, which covers standard three-phase European and UK supplies (400/415 V). Breaking capacity is 1500 A (Idm and Im), adequate for downstream fault clearing in a TN or TT system where the upstream protective device limits fault current. The RCCB is rated for pollution degree 3 (industrial or dusty environments) and operates from -25 °C to 60 °C ambient, with storage from -40 °C to 85 °C. The toggle control, padlocking option, and contact position indicator are standard for panel-building convenience.