Skip to main content
Schneider Electric A9R04463 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R04463 Acti9 iID RCCB, 63 A, 300 mA, Ty

MPNA9R04463
Active

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 4P, 63 A, 300 mA sensitivity, Type A, instantaneous, voltage-independent, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R04463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R04463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R04463 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R04463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R04463 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R04463 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R04463 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID series, rated 63 A continuous current with 300 mA earth-leakage sensitivity. The 300 mA sensitivity is the trip threshold for leakage to ground — it protects against fire risk from sustained arcing faults, not personnel shock (that requires 30 mA or lower). The trip mechanism is voltage-independent: it does not need a control voltage to operate, so it clears a ground fault even if the supply neutral is lost — a reliability advantage for safety continuity.

Clip-on mounting to a DIN rail, 72 mm wide, 91 mm tall, 73.5 mm deep — occupies 8 module pitches. Terminals accept 1…35 mm² rigid or 1…25 mm² flexible wire; strip 14 mm and torque to 3.5 N·m. IP20 finger-safe with the enclosure closed, IP40 inside a modular enclosure.

Frequently asked questions

What is the A9R04463 used for?

It is a residual current circuit breaker (RCCB) that disconnects the circuit when leakage current exceeds 300 mA, protecting against fire from ground faults. The Type A detection handles AC and pulsating DC residual currents, making it suitable for circuits with electronic loads.

Where can I buy the A9R04463?

This part is sourced to order against an RFQ through independent distribution. Submit a request for a quote to confirm current availability and pricing.

What is the A9R04463's depth?

73.5 mm.

What standards does the A9R04463 comply with?

It complies with EN/IEC 61008-1.

MPN
A9R04463