Schneider Electric A9R14463 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R14463 Acti9 iID RCCB, 63A, 300mA, 4P,

MPNA9R14463
Obsolete

Schneider Electric Acti9 iID, A9R14463, residual current circuit breaker (RCCB), 4P, 63 A, 300 mA, Type AC, instantaneous, voltage independent, clip-on DIN rail, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9R14463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R14463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R14463 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R14463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R14463 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R14463 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R14463 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID range, rated 63 A continuous with 300 mA earth-leakage sensitivity, Type AC, instantaneous trip. The 73.5 mm depth and 72 mm width fit standard modular enclosures; the white housing and left-side neutral position are typical for Acti9 panel layouts.

Rated 63 A at 380...415 V AC, 50/60 Hz — sized for the main incoming feed of a small commercial sub-board or the outgoer of a larger distribution panel. The 300 mA sensitivity is a common choice for general-purpose socket-outlet and lighting circuits where a lower 30 mA threshold would cause nuisance tripping on cable leakage. Type AC means it detects sinusoidal alternating earth-leakage currents only; if the load includes rectified or pulsed DC fault currents (e.g., from VFDs, UPS, LED drivers), a Type A or Type B RCCB is required instead. The instantaneous trip (no time delay) ensures fast disconnection on earth faults, but means it cannot be used in selective (S-type) coordination schemes where a delayed downstream RCCB is needed. Voltage-independent tripping technology means the RCCB detects leakage current using the differential transformer alone, without needing a separate supply voltage — it will trip even if the line voltage is lost or severely depressed. This is standard for electromechanical RCCBs and avoids the failure mode of electronic types that may not trip on a lost neutral.

Installation and wiring constraints

Clip-on mounting to a 35 mm DIN rail; the 9 mm pitch count of 8 means it occupies 72 mm (8 modules) of rail width. Terminals accept 1...35 mm² solid or 1...25 mm² flexible (with or without ferrule) — sized for the 63 A incoming cable. The contact position indicator and padlocking provision allow lockout/tagout during maintenance. IP20 on the terminals (finger-safe), IP40 on the modular enclosure — suitable for installation inside a distribution cabinet rated IP4X or better.

Frequently asked questions

Who supplies A9R14463 and how is it quoted for volume purchases?

The A9R14463 is sourced through independent distribution channels. Submit an RFQ for current pricing and availability; volume commitments can be scheduled against a forecast.

What is the closest alternative to A9R14463 in the Acti9 range?

Within the Acti9 iID family, the main variant difference is sensitivity (30 mA vs 300 mA) and pole count. The A9R14463 is a 4P, 63 A, 300 mA, Type AC, instantaneous unit. A 30 mA version (e.g., A9R14464) would be the direct substitute for circuits requiring personnel protection, but it is not pin-compatible — same footprint, different trip threshold.

What compliance documentation does this brand provide for A9R14463?

The A9R14463 is designed and tested to EN/IEC 61008-1. Standard compliance documentation includes the manufacturer's declaration of conformity (CE), and the product carries the relevant markings for the European market. RoHS and REACH declarations are available from the manufacturer upon request.

MPN
A9R14463