Skip to main content
Schneider Electric A9R22240 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R22240 Acti9 iID RCCB, 40 A, 100 mA, Ty

MPNA9R22240
Active

Schneider Electric Acti9 iID, RCCB, 2P, 40 A, 100 mA, Type A, 230/240 V AC, DIN rail, clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R22240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R22240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R22240 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R22240 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height96 mm
Depth69 mm
A9R22240 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R22240 — Approvals
ParameterValue
StandardsIEC 61008-2-1 AS/NZS 61008.1

Product details

The Schneider Electric A9R22240 is an Acti9 iID residual current circuit breaker (RCCB) — 2 poles, rated 40 A, with 100 mA earth-leakage sensitivity and Type A protection. It clips onto a DIN rail, occupies 4 x 9 mm pitches (36 mm wide), and is rated for 230/240 V AC 50/60 Hz networks. The instantaneous trip is voltage-independent, so it clears a fault even if the line voltage drops.

The 40 A continuous rating (In) and 1500 A making/breaking capacity (Idm/Im) cover most residential and light commercial outgoing circuits — think final subcircuits feeding socket outlets, lighting, or small loads. The 100 mA sensitivity is less sensitive than the common 30 mA; it's chosen where nuisance tripping from cable leakage or equipment inrush is a concern, or where the installation standard allows a higher threshold (e.g., some AS/NZS 3000 applications).

Frequently asked questions

Who supplies A9R22240 and how is it quoted for volume purchases?

The A9R22240 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is A9R22240's listed depth (69 mm) on this component line?

The A9R22240 has a depth of 69 mm, with an embedding depth of 44 mm into the panel.

What is A9R22240's listed range (Acti9) on this component line?