Specifications

A9R22280 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R22280 — Electrical Ratings
ParameterValue
Rated current (In)80 A
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R22280 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R22280 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height96 mm
Depth69 mm
A9R22280 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R22280 — Approvals
ParameterValue
StandardsIEC 61008-2-1 AS/NZS 61008.1

Product details

Rated at 80 A with a 100 mA sensitivity, it trips instantaneously when leakage exceeds that threshold, making it suitable for outgoer circuits where a higher threshold is needed to avoid nuisance tripping from normal leakage on longer runs or multiple loads. Rated operational voltage is 230/240 V AC at 50/60 Hz, with an insulation voltage of 500 V AC. Breaking and making capacity is 1500 A (Idm and Im), and the unit withstands 8/20 µs impulse currents up to 250 A per EN/IEC 61008-1.

Protection class and deployment context

The tripping technology is voltage independent, so the device operates without an external power supply, maintaining protection even if the line voltage drops. Mounts via clip-on to a DIN rail, occupying 4 modules of 9 mm pitch (36 mm total width). IP20 rated on the terminals (finger-safe), IP40 within a modular enclosure. The white housing has a toggle control and a contact position indicator.

Frequently asked questions

What is the A9R22280 used for?

The A9R22280 is a residual current circuit breaker (RCCB) used to protect against earth leakage faults in AC electrical installations, typically in distribution boards as an outgoer device. Its 100 mA sensitivity suits circuits with higher natural leakage, such as long cable runs or multiple loads.