Schneider Electric A9R26492

Schneider Electric A9R26492 Acti9 RCCB-ID, 4P 125A 500mA Typ

MPN A9R26492
Active

Schneider Electric Acti9 RCCB-ID, 4P, 125 A rated current, 500 mA earth-leakage sensitivity, Type A, IEC/EN 61008-1, 35 mm DIN rail mount.

$699.30 – $1,248.01 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R26492 specifications
ParameterValue
Control typeToggle
Voltage400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Insulation voltage ui400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorGrey
Depth76 mm
Width72 mm
Height86 mm
Electrical life cycles2000 cycles
Mechanical life cycles5000 cycles
Operating temperature-25...40 °C

Product details

The Schneider Electric A9R26492 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 family, rated 125 A with 500 mA earth-leakage sensitivity and Type A protection. The 125 A rating makes it a main-switch or heavy-feeder RCCB for commercial or industrial sub-distribution, not a final-circuit device. The 500 mA sensitivity is a selectivity threshold: it sits upstream of 30 mA RCCBs so that a downstream fault trips the local device first, keeping the main board live.

Rated breaking and making capacity is 1250 A at both 400 V and 230 V, per IEC/EN 61008-1 and -2-1. That is the short-circuit withstand of the RCCB itself — not a high-breaking MCB, but adequate for the fault levels typically seen downstream of a 125 A feeder in a commercial panel. The rated insulation voltage (Ui) and operational voltage (Ue) are both 400 V AC 50 Hz, confirming it is a 3-phase / 4-wire device (400 V line-to-line). Mechanical durability is 5000 cycles; electrical durability is 2000 cycles. That is a standard duty rating for a distribution RCCB — not intended for frequent switching, but fine for its role as a protective device that operates only on fault or during maintenance isolation. The toggle control and red/green trip indicator give clear local status; the padlock provision lets you lock it off for safe downstream work. Terminals accept up to 50 mm² rigid or 35 mm² flexible cable — enough for the 125 A feed. Tightening torque is 3 N·m; strip length is 11 mm. The tunnel-type terminals take two cables per pole up to 16 mm², useful for looping through to another device.

Mounting and enclosure fit

The 4-pole body takes 8 x 9 mm pitches (72 mm wide), 86 mm tall, 76 mm deep. IP20 on the terminals, IP40 inside a modular enclosure — standard for distribution boards.

MPN
A9R26492