Skip to main content
Schneider Electric A9R31440

A9R31440 Acti9 iID RCCB, 4P 40A 30mA Type A-SI, 380-415V

MPN A9R31440
Active

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 4P, 40 A rated current, 30 mA earth-leakage sensitivity, Type A-SI (Super Immunised), 380...415 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R31440 specifications
ParameterValue
Control typeToggle
Voltage380...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width72 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9R31440 is a 4-pole Acti9 iID residual current circuit breaker (RCCB) rated for 40 A continuous current with a 30 mA earth-leakage trip threshold. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents from electronics (VFDs, switched-mode supplies) without nuisance tripping — a common pain point in modern industrial panels.

The 30 mA sensitivity is the standard for personnel protection (direct-contact shock prevention) per IEC 60364. The 40 A rated current matches a 3-phase outgoing feeder for a sub-distribution board or a large machine supply. Breaking capacity is rated at Idm 1500 A and Im 1500 A — adequate for most final circuits where the upstream MCB or fuse already limits fault current below that level. Type A-SI (Super Immunised) adds immunity to high-frequency leakage currents and transient surges that would trip a standard Type A RCCB. The voltage-independent tripping mechanism means the device detects leakage even if the phase voltage collapses — it does not rely on an electronic circuit for the trip decision. This is a key reliability feature for safety-critical circuits. The 8/20 µs impulse withstand of 3000 A confirms it survives lightning-induced or switching surges on the line side without internal damage.

Clip-on DIN rail mounting, neutral on the left side. Terminals accept up to 35 mm² rigid or 25 mm² flexible wire; strip length 14 mm, tighten to 3.5 N·m. The 72 mm width (8 x 9 mm pitches) fits standard modular enclosure spacing.

MPN
A9R31440