Skip to main content
Schneider Electric A9R46492 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R46492 Acti9 RCCB-ID, 4P, 125 A, 500 mA

MPNA9R46492
Active

Schneider Electric Acti9 RCCB-ID, 4P, 125 A, 500 mA, Type B, 400 V AC, IEC/EN 61008-1, A9R46492.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9R46492 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)500 mA
Earth-leakage protection class / typeType B
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationRed/green indicator Trip indicator
A9R46492 — Electrical Ratings
ParameterValue
Rated current (In)125 A
Rated operational voltage (Ue)400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
Rated impulse withstand voltage (Uimp)4 kV conforming to IEC/EN 61008-1 4 kV conforming to IEC/EN 61008-2-1
Device location in systemOutgoer
Electrical durability2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9R46492 — Identification
ParameterValue
Product nameActi9 RCCB-ID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameRCCB-ID
A9R46492 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminals2 cable(s) 1.5...16 mm² flexible Tunnel type terminals2 cable(s) 1.5...16 mm² rigid Tunnel type terminals1 cable(s) 1.5...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible Tunnel type terminals1 cable(s) 1.5...35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5...16 mm² flexible with ferrule
Wire stripping length11 mm
Terminal tightening torque3 N.m
Width72 mm
Height86 mm
Depth76 mm
A9R46492 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20 conforming to IEC/EN 60529 IP20 conforming to IEC/EN 62423 IP40 (modular enclosure) conforming to IEC/EN 60529 IP40 (modular enclosure) conforming to IEC/EN 62423
Pollution degree3
A9R46492 — Approvals
ParameterValue
StandardsIEC/EN 61008-1 IEC/EN 61008-2-1 IEC/EN 62423

Product details

The Schneider Electric A9R46492 is a 4-pole Acti9 RCCB-ID residual current circuit breaker rated at 125 A with a 500 mA earth-leakage sensitivity, Type B, for 400 V AC 50 Hz networks. The instantaneous trip characteristic means it clears earth faults without intentional delay — suited for outgoing circuits where fast disconnection is required.

The Type B classification means this RCCB detects AC sinusoidal, pulsating DC, and smooth DC fault currents up to 500 mA — a requirement for circuits with variable-speed drives, UPS systems, or other power-electronics loads that can generate DC leakage. The 125 A rated current and 400 V operational voltage position it for main or sub-main distribution in commercial and industrial panels. The 3 kA impulse withstand (8/20 µs) per IEC/EN 61008-1 gives it reasonable surge immunity for typical installation environments.

The tunnel-type terminals accept up to 50 mm² rigid or 35 mm² flexible cable per pole. Tightening torque is 3 N·m, and wire stripping length is 11 mm. The red/green trip indicator gives local status at a glance. IP20 body protection is typical for enclosed distribution boards; the modular enclosure achieves IP40 within the panel.

Frequently asked questions

What is the closest alternative to A9R46492 in the Acti9 range?

Within the Acti9 RCCB-ID family, the closest alternative would be a different sensitivity or pole count variant — for example, a 4P 125 A Type B with 300 mA sensitivity (order code A9R46491). The only spec difference is the earth-leakage sensitivity; form, fit, and function are otherwise identical.

Where can I buy A9R46492?

The A9R46492 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for A9R46492?

The A9R46492 carries a VDE quality label and is certified to IEC/EN 61008-1, IEC/EN 61008-2-1, and IEC/EN 62423. These standards cover residual current circuit-breaker performance, immunity, and test requirements.

MPN
A9R46492