Skip to main content
Schneider Electric A9R71463 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R71463 Acti9 iID RCCB, 63 A, 30 mA, 4P

MPNA9R71463
Active

Schneider Electric Acti9 iID RCCB, 4P, 63 A rated, 30 mA Type AC earth leakage, 380-415 V AC, DIN rail clip-on, EN/IEC 61008-1.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R71463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R71463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R71463 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R71463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R71463 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R71463 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R71463 is a 4-pole Acti9 iID residual current circuit breaker (RCCB) rated for 63 A continuous load on a 380-415 V AC 50/60 Hz network.

Clip-on DIN rail mount, 8 x 9 mm pitch modules wide (72 mm). Neutral on the left, poles labelled for standard panel layout. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible; strip 14 mm, torque to 3.5 N.m.

Current-production part in the Acti9 range.

63 A rated current (In) matches the main switch or upstream MCB rating for a 3-phase submain. 30 mA sensitivity is the standard for socket-outlet and general-purpose circuits in most IEC countries — catches body-contact faults without nuisance tripping on normal leakage from filters or VFDs. Voltage-independent tripping means the device breaks the circuit on a ground fault even if the phase voltage collapses — no auxiliary supply needed.

Frequently asked questions

What is A9R71463's depth?

73.5 mm, which is the standard depth for an 8-module-wide Acti9 RCCB — fits most DIN-rail enclosures without a deep lid.

What standard does A9R71463 comply with?

EN/IEC 61008-1 — the IEC standard for residual current operated circuit-breakers without integral overcurrent protection (RCCBs).

MPN