Skip to main content
Schneider Electric A9R91263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R91263 Acti9 iID RCCB, 63A 30mA 2P Type

MPNA9R91263
Active

Schneider Electric Acti9 iID, Residual current circuit breaker (RCCB), 2P, 63 A, 30 mA, Type A-SI, 220...240 V AC, clip-on DIN rail, white.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R91263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R91263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R91263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R91263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73.5 mm
A9R91263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R91263 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R91263 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID series, rated at 63 A with 30 mA earth-leakage sensitivity. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents and is immune to nuisance tripping from high-frequency leakage typical of modern switched-mode power supplies and inverters.

Terminals accept up to 35 mm² rigid or 25 mm² flexible, with a stripping length of 14 mm and a tightening torque of 3.5 N.m. The 36 mm width (4 modules) fits standard enclosures; the toggle actuator and padlocking provision allow lockout/tagout without removing the device. IP20 body, IP40 inside a modular enclosure — fine for clean indoor panels, not for washdown zones.

Rated operational voltage is 220...240 V AC at 50/60 Hz, with an insulation voltage of 500 V AC. The breaking capacity (Idm/Im) is 1500 A. Electrical durability is 15,000 cycles under AC-1 load; mechanical durability is 20,000 cycles. The residual current tripping is voltage-independent, so it clears faults even if the supply neutral is lost — a key safety feature for personnel protection. Ambient operating range is -25 to 60 °C, storage -40 to 85 °C, with pollution degree 3 (conductive pollution or dry non-conductive that becomes conductive).

Frequently asked questions

What is the A9R91263 used for?

It is a 2-pole residual current circuit breaker (RCCB) used for earth-leakage protection in final distribution boards, rated 63 A, 30 mA sensitivity, Type A-SI (Super Immunised). It protects against earth faults in AC circuits and is immune to nuisance tripping from high-frequency leakage.

What is the closest alternative to the A9R91263?

Within the Acti9 iID family, the closest alternative is a unit with the same 2-pole, 63 A, 30 mA rating but a different earth-leakage protection class (e.g., Type A instead of Type A-SI). The Type A-SI (Super Immunised) variant is specifically designed for installations with high-frequency leakage from electronics — a standard Type A may nuisance-trip in such environments.

Where can I buy the A9R91263?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
A9R91263