Schneider Electric Acti9 ISW 40...125, 2P 100A isolator, 2.5 kA breaking capacity, 415 V AC, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9S2P100 specifications
ParameterValue
Range of productISW 40...125
Product or component typeIsolator
Short-circuit withstand20 A
Supply voltage48 V DC 1P 100 V DC 2P
Voltage6 kV
[Uimp] rated impulse withstand voltage500 V
Breaking capacity2.5 kA
[Ie] rated operational current100 A at 240 V AC
Poles description2P
Utilisation categoryAC-22
Pollution degree3
StandardsIEC 60669-1 IEC 60947-3
RangeActi9
Device applicationIsolation
Product destinationDistribution board
Total number of 18 mm modules2
Ambient air temperature for operation-20...50 °C

Product details

The A9S2P100 is a 2-pole 100 A isolator from the Schneider Electric Acti9 ISW 40...125 range, designed for isolation duty in distribution boards. It complies with IEC 60669-1 and IEC 60947-3, rated for AC-22 utilisation category — meaning it handles mixed resistive and inductive loads, typical for general distribution isolation. The 2.5 kA rated breaking capacity suits it for downstream isolation where fault levels are moderate.

Sourcing reality — obsolete part

Schneider has marked the A9S2P100 as obsolete. The 2-module 18 mm footprint and 100 A AC-22 rating are the specs to match if evaluating a drop-in from another manufacturer's range.

The 100 A rating at 240 V AC is the headline — this isolator handles full panel feed or large subfeed isolation. The 2.5 kA breaking capacity is not a high-fault device; it's intended for isolation, not fault clearing upstream of a breaker. The DC rating is split: 48 V DC for single-pole use, 100 V DC for both poles in series — useful for battery-bank or DC distribution isolation. The 500 V impulse withstand and 6 kV rated insulation voltage give it headroom for 400 V AC systems with typical surge environments.

Frequently asked questions

Where can I buy A9S2P100 and get a price?

The A9S2P100 is sourced through independent distribution channels. Submit an RFQ — availability and current pricing are confirmed at quote time against your order quantity.

What is the closest alternative to A9S2P100?

No official successor order code is published in the lifecycle record. A replacement would need to match the 2-pole 100 A AC-22 rating, 2.5 kA breaking capacity, and 2-module 18 mm DIN-rail footprint. A parametric cross-reference from the same Acti9 ISW family or a third-party equivalent should be evaluated against those specs.

What standards does A9S2P100 comply with?

It complies with IEC 60669-1 (switches for household and similar fixed-electrical installations) and IEC 60947-3 (switches, disconnectors, switch-disconnectors and fuse-combination units for low-voltage switchgear and controlgear).