Skip to main content
Schneider Electric A9S68191

Schneider Electric A9S68191 Acti9 iINT Switch Disconnector,

MPN A9S68191
Obsolete

Schneider Electric Acti9 iINT, switch disconnector, 1P, 100 A, 240 V AC, AC-22A, DIN rail, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9S68191 key specifications
ParameterValue
Control typeToggle
Main product or component typeSwitch disconnector
Voltage240 V AC 50/60 Hz
Insulation voltage ui250 V AC 50/60 Hz
Current100 A at 230 V AC 50/60 Hz
Utilization categoryAC-22 A
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9S68191 additional specifications
ParameterValue
Pollution degree3
ColorWhite
Depth73 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationControl Isolation
Operating temperature-25...60 °C

Product details

Control isolation switch disconnector, 1P, 100 A, AC-22A

The Schneider Electric A9S68191 is a 1-pole Acti9 iINT switch disconnector rated 100 A at 230 V AC and 240 V operational voltage, in utilisation category AC-22A for switching resistive and mixed resistive-inductive loads including moderate motor loads. It is designed for control isolation duty and certified for isolation per GB 14048.3, with a visible contact gap and ON/OFF indication confirming the disconnected state.

The AC-22A utilisation category (100 A at 230 V) covers on/off switching of resistive and mixed loads including small motors, heaters, and lighting banks — the most common duty for a panel isolation switch. Rated insulation voltage is 250 V AC with a 6 kV impulse withstand, so it is sized for 240 V line-to-neutral circuits in pollution degree 3 environments (industrial panels with conductive contamination).

Tunnel-type terminals accept 6 to 50 mm² rigid or 6 to 35 mm² flexible conductors (with or without ferrule), with a 14 mm strip length and 3.5 N.m tightening torque. The 18 mm width on DIN rail leaves room for adjacent devices in a crowded enclosure. Top or bottom busbar and distribution-block compatibility is confirmed, so common power distribution schemes work without extra adapters.

MPN
A9S68191