Skip to main content
Schneider Electric A9TAA1225 — 2-Pole MCB (DIN Rail)

Schneider Electric A9TAA1225 Acti9 ARC iC60, Arc Fault Detec

MPNA9TAA1225
Active

Schneider Electric Acti9 ARC iC60 arc fault detection add-on block, 2P, 25 A, 230 V AC, DIN rail clip-on, EN/IEC 62606.

$256.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9TAA1225 — Identification
ParameterValue
Product nameActi9 ARC iC60
Product rangeActi9
Device short nameARC iC60
Product / component typeArc fault detection add-on block
A9TAA1225 — Electrical
ParameterValue
Rated current [In]25 A
Pole configuration2P
Rated operational voltage [Ue]230 V AC 50 Hz conforming to IEC 62606
Network type (AC/DC)AC
Network frequency50 Hz
A9TAA1225 — Protection
ParameterValue
Overvoltage categoryIII
Mechanical durability (cycles)20000 cycles
A9TAA1225 — Mechanical
ParameterValue
9 mm pitches2
Width54 mm
Height91 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal1...10 mm² flexible Tunnel type terminal1...16 mm² rigid
Terminal tightening torque2 N.m
Local signalling / indicationON, OFF, fault trip LED arc fault diagnostic
A9TAA1225 — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9TAA1225 — Approvals
ParameterValue
Standards / complianceEN/IEC 62606

Product details

The Schneider Electric A9TAA1225 is an arc fault detection add-on block from the Acti9 ARC iC60 range. It is a 2-pole device rated at 25 A, designed to detect series and parallel arc faults in final circuits per EN/IEC 62606.

The 25 A rated current (In) and 230 V AC rated operational voltage (Ue) define the circuit it protects — a 25 A final subcircuit on a 230 V single-phase supply. The 400 V AC rated insulation voltage (Ui) and 4 kV rated impulse withstand voltage (Uimp) confirm it handles transient overvoltages in overvoltage category III installations, typical for fixed-wiring distribution boards. The 10 000-cycle electrical durability at 230 V AC and 20 000-cycle mechanical durability give the expected service life under normal switching and fault conditions.

Tunnel terminals accept 1…10 mm² flexible or 1…16 mm² rigid conductors; tighten to 2 N·m after stripping 14 mm of insulation. The block is an outgoer device in the system, so it sits downstream of the main switch or incoming device. Pollution degree 2 and IP20 front-face protection suit it for enclosed distribution boards in clean indoor environments.

Frequently asked questions

What standard does A9TAA1225 comply with?

It complies with EN/IEC 62606, the standard for arc fault detection devices (AFDDs).

What is the A9TAA1225 rated current and voltage?

Rated current (In) is 25 A; rated operational voltage (Ue) is 230 V AC.

How is the A9TAA1225 mounted?

It clips onto a 35 mm DIN rail, occupies 2 x 9 mm pitches, and connects to an MCB via screw terminals.

Where can I buy A9TAA1225 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN