Schneider Electric A9TAA1240 — 2-Pole MCB (DIN Rail)

Schneider Electric Acti9 ARC iC60 A9TAA1240, 2P 40A Arc Faul

MPNA9TAA1240
Active

Schneider Electric Acti9 ARC iC60 arc fault detection add-on block, 2P, 40 A, 230 V AC, DIN rail clip-on, EN/IEC 62606.

$261.79Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9TAA1240 — Identification
ParameterValue
Product nameActi9 ARC iC60
Product rangeActi9
Device short nameARC iC60
Product / component typeArc fault detection add-on block
A9TAA1240 — Electrical
ParameterValue
Rated current [In]40 A
Pole configuration2P
Rated operational voltage [Ue]230 V AC 50 Hz conforming to IEC 62606
Network type (AC/DC)AC
Network frequency50 Hz
A9TAA1240 — Protection
ParameterValue
Overvoltage categoryIII
Mechanical durability (cycles)20000 cycles
A9TAA1240 — Mechanical
ParameterValue
9 mm pitches2
Width54 mm
Height91 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal1...10 mm² flexible Tunnel type terminal1...16 mm² rigid
Terminal tightening torque2 N.m
Local signalling / indicationON, OFF, fault trip LED arc fault diagnostic
A9TAA1240 — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9TAA1240 — Approvals
ParameterValue
Standards / complianceEN/IEC 62606

Product details

Arc fault detection add-on block for the Acti9 iC60 range

The Schneider Electric A9TAA1240 is an Acti9 ARC iC60 arc fault detection add-on block, 2P, rated 40 A at 230 V AC per EN/IEC 62606. The 40 A rating means this block is sized for a 40 A branch circuit — match it to the same-rated iC60 breaker to protect the full load current. The 2P (two-pole) format with neutral left suits single-phase or split-phase panels where both poles are switched.

Clip-on mounting on a DIN rail, 2 module pitches (9 mm each) wide — 54 mm total width, 73 mm depth, 91 mm height. Occupies two standard 18 mm slots in the enclosure. Terminal tunnels accept 1–10 mm² flexible or 1–16 mm² rigid copper; strip 14 mm, torque to 2 N·m. Ambient operating range -25 to 60 °C, storage -40 to 85 °C, 95 % RH at 55 °C.

Frequently asked questions

How do I get current pricing and availability for A9TAA1240?

The A9TAA1240 is sourced and quoted to order against an RFQ through independent distribution. Contact us for a firm quote — availability and current pricing are confirmed at quote time.

What is A9TAA1240's listed depth (73 mm) on this component line?

The A9TAA1240 has a depth of 73 mm, width of 54 mm (2 x 9 mm pitches), and height of 91 mm. It clips onto a DIN rail.

What compliance documentation does this brand provide for A9TAA1240?

The A9TAA1240 is certified to EN/IEC 62606 and carries the NF quality label. Tropicalisation severity B per IEC 60068-2-30 for 28 days. IP20, pollution degree 2, overvoltage category III.

MPN
A9TAA1240