Specifications

A9TAB2225 — Residual Current Protection
ParameterValue
Local signalling / indicationON, OFF, fault trip LED arc fault diagnostic
A9TAB2225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230 V AC 50 Hz conforming to IEC 62606
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)250 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV conforming to IEC 62606
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability10000 cycles 230 V AC conforming to IEC 62606
Mechanical durability (operating cycles)20000 cycles
A9TAB2225 — Identification
ParameterValue
Product nameActi9 Active ARC iC60
Product / component typeActive arc fault detection add-on block
Device short nameARC iC60
A9TAB2225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules2
Terminal connectionsTunnel type terminal1...10 mm² flexible Tunnel type terminal1...16 mm² rigid
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width54 mm
Height91 mm
Depth73 mm
A9TAB2225 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20
Pollution degree2 conforming to IEC 62606
Relative humidity95 % at 55 °C
TropicalisationSeverity B conforming to IEC 60068-2-30 for 28 d
A9TAB2225 — Approvals
ParameterValue
StandardsEN/IEC 62606

Product details

The A9TAB2225 is a Schneider Electric Acti9 Active ARC iC60 active arc fault detection add-on block, designed to clip onto the left side of a compatible Acti9 iC60 miniature circuit breaker (MCB). It monitors the downstream circuit for series and parallel arc faults, tripping the host MCB when it detects the characteristic high-frequency noise of an arc, per EN/IEC 62606. This is a 2-pole (2P) unit rated at 25 A, 230 V AC, 50 Hz, intended for outgoer positions in final distribution boards.

The 25 A rated current (In) matches the host MCB rating. The 230 V AC operational voltage is standard single-phase final circuit level. Wire connections are tunnel-type terminals accepting 1...10 mm² flexible or 1...16 mm² rigid cable, with a tightening torque of 2 N.m and a strip length of 14 mm. The electrical connection to the MCB is via screws, so the block physically bridges onto the breaker's line-side terminals.

Deployment context and compliance

This block is designed for use in final distribution boards (outgoer location) in commercial and industrial installations where arc fault protection is required by local codes or insurance specifications. It is certified to EN/IEC 62606 (the standard for arc fault detection devices, AFDDs). The pollution degree is 2 (normal, non-conductive pollution only), overvoltage category III (distribution level). It carries the IMQ quality label (Italian mark). The unit is tropicalised to severity B per IEC 60068-2-30 for 28 days, meaning it withstands damp heat cycling. It is compatible with the EcoStruxure Panel Server range (Entry, Advanced, Universal) for data recording and remote monitoring of event logs, maintenance indicators, and date/time-stamped trip events.

Frequently asked questions

What is A9TAB2225's listed depth (73 mm) on this component line?

The depth is 73 mm. This is the dimension from the DIN rail mounting face to the front of the block, including the screw terminals.

MPN
A9TAB2225