Skip to main content
Schneider Electric A9TAB2240

Schneider Electric A9TAB2240 Acti9 ARC iC60, 40 A, 2P, Activ

MPN A9TAB2240
Active

Schneider Electric Acti9 Active ARC iC60, active arc fault detection add-on block, 40 A, 2P, 230 V AC, clip-on DIN rail, EN/IEC 62606.

$388.31 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TAB2240 specifications
ParameterValue
Voltage230 V AC 50 Hz conforming to IEC 62606
Insulation voltage ui250 V AC 50 Hz
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to IEC 62606
ColorWhite (RAL 9003)
Depth73 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles 230 V AC conforming to IEC 62606
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...40 °C

Product details

The Schneider Electric A9TAB2240 is an active arc fault detection add-on block from the Acti9 ARC iC60 range. It clips onto the side of a compatible Acti9 MCB (iC60 series) via the clip-on mounting, adding arc-fault, overvoltage, and earth leakage event management to the outgoing circuit. Rated at 40 A and 2 poles, it operates on a 230 V AC, 50 Hz network and conforms to EN/IEC 62606 — the standard for arc fault detection devices (AFDDs).

The 40 A rated current ([In]) sets the maximum continuous load this block can monitor and protect. It is sized for final subcircuits — outgoer position — not incoming mains. The 230 V AC rated operational voltage (Ue) matches standard single-phase residential and light commercial supplies. The threshold tripping voltage of 275 V (+/- 5 V) means it triggers an overvoltage event when line voltage exceeds that level, protecting downstream loads from sustained overvoltage conditions. Accuracy on voltage and current is +/- 2 %, power +/- 5 % — sufficient for energy monitoring and fault diagnostics, not for revenue-grade metering.

Installation and integration notes

Clip-on mounting to the iC60 MCB; the add-on block connects electrically to the MCB via screws. Neutral is on the left. Terminals accept 1 to 10 mm² flexible or 1 to 16 mm² rigid wire. Wire stripping length is 14 mm. The block is IP20 — suitable for dry indoor panels only, not washdown or outdoor locations. Pollution degree 2 (non-conductive pollution only, occasional condensation). Rated for tropicalised environments: severity B per IEC 60068-2-30 for 28 days. Local signalling includes ON/OFF status, fault trip LED, and arc fault diagnostic LED.

Carries IMQ quality label. Overvoltage category III. Pollution degree 2. Electrical durability: 10,000 cycles at 230 V AC per IEC 62606; mechanical durability: 20,000 cycles. Compatible with EcoStruxure Panel Server concentrators (Entry, Advanced, Universal) for remote monitoring and data recording.

MPN
A9TAB2240