Skip to main content
Schneider Electric A9TAB2625

Schneider Electric A9TAB2625 Acti9 iC40 ARC, 25 A, 1P+N, Arc

MPN A9TAB2625
Active

Schneider Electric Acti9 Active ARC iC40, A9TAB2625, 25 A, 1P+N, 230 V AC, arc fault detection add-on block, EN/IEC 62606, IP20, DIN rail clip-on, 2-module width (36 mm).

$353.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TAB2625 specifications
ParameterValue
Voltage230 V AC 50 Hz conforming to IEC 62606
Insulation voltage ui250 V AC 50 Hz
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2 conforming to IEC 62606
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles 230 V AC conforming to IEC 62606
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...40 °C

Product details

The A9TAB2625: The 25 A rated current (In) is the continuous load the block is designed to pass; match it to the upstream MCB's rating for coordinated arc-fault protection. The 275 V ±5 V overvoltage threshold trips the internal mechanism when line voltage exceeds that window — useful for catching neutral-to-earth faults or sustained swells that can ignite an arc. Accuracy on voltage and current is ±2 %, power ±5 %, so the event-logging data is repeatable enough for post-incident analysis. The IP20 housing keeps fingers out but is not sealed; mount inside a closed panel.

Clip-on mounting on DIN rail, neutral on the left. The tunnel-type terminals accept 1–10 mm² flexible or 1–16 mm² rigid; strip length 14 mm, tighten to 2 N·m. The block connects to the MCB by screws — no separate busbar needed. Local signalling includes ON/OFF status, a fault-trip LED, and an arc-fault diagnostic LED for troubleshooting without a meter. Electrical durability is 10,000 cycles at 230 V AC per IEC 62606; mechanical durability is 20,000 cycles. The block records date/time and maintenance indicators, and is compatible with EcoStruxure Panel Server concentrators for remote monitoring.

MPN