Skip to main content
Schneider Electric A9TDEC610 — Residual Current Breakers (RCCB/RCBO)

Schneider A9TDEC610 Acti9 iCV40N ARC, 10 A, Type B, 6 kA

MPNA9TDEC610
Active

Schneider Electric Acti9 Active iCV40N ARC arc-fault detection circuit breaker, A9TDEC610, 10 A rated, Type B curve, 1P+N, 6 kA breaking capacity, DIN rail mount, white (RAL 9003).

$359.91Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9TDEC610 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip LED arc fault diagnostic
A9TDEC610 — Electrical Ratings
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)230 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)250 V AC 50 Hz between phase and neutral
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles 230 V AC 50 Hz
Mechanical durability (operating cycles)20000 cycles
A9TDEC610 — Identification
ParameterValue
Product nameActi9 Active iCV40 ARC
Product / component typeActive arc fault detection RCBO
Product range / familyActi9
Device short nameiCV40N ARC
A9TDEC610 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width36 mm
Height91 mm
Depth73 mm
A9TDEC610 — Environmental
ParameterValue
Operating ambient temperature-25...50 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2 conforming to EN/IEC 62606
Relative humidity95 % at 55 °C
Operating altitude2000 m
TropicalisationSeverity B conforming to IEC 60068-2-30 for 28 d
A9TDEC610 — Approvals
ParameterValue
StandardsEN/IEC 62606 EN/IEC 61009-1 EN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The 6 kA Icn (service breaking capacity) is the guaranteed short-circuit interruption rating for the circuit it protects; the 10 kA Icu (ultimate breaking capacity) is the maximum fault it can clear once and remain functional. For a 1P+N board, that covers most final sub-circuits in a domestic or small commercial distribution board. The arc-fault detection (AFDD) function monitors for series and parallel arcs — loose connections, damaged cables, or carbonized insulation — and trips the breaker before the fault escalates. It meets EN/IEC 62606, the standard for arc-fault detection devices. The thermal-magnetic trip unit handles the overload and short-circuit protection; the electronics handle the arc signature analysis. Mounting is clip-on to a DIN rail (35 mm per EN 60715) with top and bottom cable entry.

Frequently asked questions

What is the closest pin-compatible alternative to A9TDEC610 in this component family?

Within the Acti9 Active iCV40 series, the A9TDEC610 is the 10 A Type B arc-fault detection variant. Other current ratings (e.g., 16 A, 20 A) and curve types (C, D) share the same physical footprint and DIN-rail mounting, so the mechanical fit is identical; the electrical ratings differ. No direct pin-compatible drop-in with the same arc-fault function exists outside the iCV40N ARC family.

Where can I buy A9TDEC610 and what is the lead time?

The A9TDEC610 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here, but we quote promptly.

What compliance documentation does this brand provide for A9TDEC610?

The A9TDEC610 carries the OVE quality label and is designed to EN/IEC 62606, EN/IEC 61009-1, EN/IEC 60947-2, and EN/IEC 61009-2-1. It also meets pollution degree 2, overvoltage category III, and tropicalisation severity B per IEC 60068-2-30. RoHS and REACH declarations are standard from Schneider Electric for this series.

MPN