Schneider Electric A9TPD4610 — 1-Pole MCB (DIN Rail)

Schneider Electric A9TPD4610 Acti9 iC40N ARC, 10A B-Curve AF

MPNA9TPD4610
Active

Schneider Electric Acti9 iC40N ARC arc fault detection circuit breaker, A9TPD4610, 10 A, B-curve, 1P+N, 6 kA Icn / 10 kA Icu, DIN-rail mount.

$256.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9TPD4610 — Identification
ParameterValue
Product nameActi9 iC40 ARC
Product / component typeArc fault detection circuit breaker
Product rangeActi9
Device short nameiC40N ARC
Poles description1P + N
Number of protected poles1
A9TPD4610 — Electrical & Protection
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)230 V AC 50 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9TPD4610 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal 1...10 mm² flexible Tunnel type terminal 1...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height91 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
A9TPD4610 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
A9TPD4610 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1 EN/IEC 60947-2 EN/IEC 62606
A9TPD4610 — Electrical
ParameterValue
[Ui] rated insulation voltage250 V AC
[Uimp] rated impulse withstand voltage4 kV

Product details

Arc fault detection breaker for final subcircuits

Rated 10 A with a B-curve (magnetic trip 3–5× In), it is sized for lighting and general-purpose final subcircuits where series arcing from loose connections or damaged conductors is a risk. The dual breaking capacity — 6 kA Icn per EN/IEC 60898-1 and 10 kA Icu per EN/IEC 60947-2 — means it meets both domestic and industrial coordination requirements on the same outgoer.

The B-curve trips between 3 and 5 times rated current (30–50 A for this 10 A unit), which suits resistive and lighting loads with low inrush — not motor or transformer circuits where a C or D curve would be needed to avoid nuisance trips. The limitation class 3 rating means it limits let-through energy under fault conditions, which helps with downstream cable protection and reduces the required cable cross-section in some installations.

Clip-on mounting to DIN rail, 36 mm width (4 × 9 mm pitches), fits standard distribution boards and sub-distribution panels. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible copper; tightening torque is 2 N·m. The toggle control with ON/OFF/fault-trip LED provides local arc fault diagnostics — the LED distinguishes an arc trip from an overcurrent trip, which cuts troubleshooting time on a tripped circuit. IP20 finger-safe protection is suitable for enclosed panel mounting.

Certified to EN/IEC 60898-1 (MCB standard), EN/IEC 60947-2 (industrial circuit-breaker standard), and EN/IEC 62606 (arc fault detection device standard). OVE quality label for Austrian market. Tropicalisation severity B per IEC 60068-2-30 for 28 days — the part is tested for damp-heat cyclic conditions, relevant for installations in non-conditioned spaces or humid environments.

Frequently asked questions

What is A9TPD4610 used for?

It is an arc fault detection circuit breaker (AFDD) for final subcircuits, combining overcurrent protection (10 A, B-curve) with series arc-fault detection in a single 1P+N module. It is used on lighting and general-purpose circuits where damaged conductors or loose connections could cause arcing.

Where can I buy A9TPD4610?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the difference between the iC40N ARC and a standard MCB?

The iC40N ARC adds series arc-fault detection per EN/IEC 62606 on top of the thermal-magnetic overcurrent protection. A standard MCB (like the iC40N without ARC) only protects against overload and short-circuit — it cannot detect the low-level arcing from a loose terminal or pinched cable that an AFDD catches.