Skip to main content
Schneider Electric A9TPD4620 — 1-Pole MCB (DIN Rail)

Schneider Electric A9TPD4620 Acti9 iC40N ARC, 20 A, B Curve,

MPNA9TPD4620
Active

Schneider Electric Acti9 iC40N ARC, arc fault detection circuit breaker, 1P+N, 20 A, B curve, 6 kA Icn, DIN rail, white (RAL 9003).

$256.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9TPD4620 — Identification
ParameterValue
Product nameActi9 iC40 ARC
Product / component typeArc fault detection circuit breaker
Product rangeActi9
Device short nameiC40N ARC
Poles description1P + N
Number of protected poles1
A9TPD4620 — Electrical & Protection
ParameterValue
Rated current (In)20 A
Rated operational voltage (Ue)230 V AC 50 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9TPD4620 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal 1...10 mm² flexible Tunnel type terminal 1...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height91 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
A9TPD4620 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
A9TPD4620 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1 EN/IEC 60947-2 EN/IEC 62606
A9TPD4620 — Electrical
ParameterValue
[Ui] rated insulation voltage250 V AC
[Uimp] rated impulse withstand voltage4 kV

Product details

The 20 A rating and 6 kA Icn (per EN/IEC 60898-1) cover standard domestic or light commercial final subcircuits at 230 V AC 50 Hz.

Breaking capacity is the headline check: the A9TPD4620 carries three figures. The 6 kA Icn at 230 V AC (EN/IEC 60898-1) is the rated short-circuit capacity for a domestic MCB — enough for most residential boards. The 10 kA Icu (EN/IEC 60947-2) is the industrial rating, covering higher fault-current panels. The 3 kA Icn1 is a lower conditional rating; ignore it unless the supply impedance is unusually high. The limitation class 3 means it lets through very little let-through energy (I²t) on a fault — helps with downstream selectivity and reduces arc-flash risk at the panel.

Integration notes

Frequently asked questions

What is A9TPD4620's listed depth (73 mm) on this component line?

The A9TPD4620 has a depth of 73 mm, which fits standard distribution board enclosures without protruding past the gland plate.

What is A9TPD4620's listed range (Acti9) on this component line?

The A9TPD4620 belongs to the Schneider Electric Acti9 range, specifically the iC40N ARC series of arc fault detection circuit breakers.

MPN
A9TPD4620