Schneider Electric A9TPE4610 — 1-Pole MCB (DIN Rail)

Schneider Electric A9TPE4610 Acti9 iC40 ARC, 10 A C-curve AF

MPNA9TPE4610
Active

Schneider Electric Acti9 iC40 ARC arc fault detection circuit breaker, A9TPE4610, 1P+N, 10 A, C-curve, 6 kA Icn per EN/IEC 60898-1, 10 kA Icu per EN/IEC 60947-2.

$256.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9TPE4610 — Identification
ParameterValue
Product nameActi9 iC40 ARC
Product / component typeArc fault detection circuit breaker
Product rangeActi9
Device short nameiC40 ARC
Poles description1P + N
Number of protected poles1
A9TPE4610 — Electrical & Protection
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)230 V AC 50 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9TPE4610 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal 1...10 mm² flexible Tunnel type terminal 1...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height91 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
A9TPE4610 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
A9TPE4610 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1 EN/IEC 60947-2 EN/IEC 62606
A9TPE4610 — Electrical
ParameterValue
[Ui] rated insulation voltage250 V AC
[Uimp] rated impulse withstand voltage4 kV

Product details

The Schneider Electric A9TPE4610 is an Acti9 iC40 ARC arc fault detection circuit breaker (AFDD) — a 1P+N device rated 10 A with a C-curve magnetic trip of 5...10 x In. The arc fault detection electronics monitor the line for series and parallel arc faults, and the local signalling includes a dedicated LED for arc fault diagnostics — so when the breaker trips, you know whether it was an overload/short or an arc event. The 3 kA Icn1 rating at 230 V AC is a lower conditional rating for specific coordination — the 6 kA Icn is the one to use for general branch-circuit protection. The part also complies with EN/IEC 62606, the arc fault detection device standard, so it covers all three: MCB, MCCB, and AFDD requirements in one DIN-rail module.

Clip-on mounting to DIN rail, 36 mm wide (4 x 9 mm pitches), 91 mm tall, 73 mm deep. Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible, with a 2 N.m tightening torque and 14 mm strip length. Cable entry from top and bottom, neutral on the left. IP20 finger-safe terminals — fine for enclosed panelboards, not for wet locations. Tropicalisation severity B per IEC 60068-2-30 for 28 days means it handles high-humidity environments without condensation damage.

Frequently asked questions

What is the breaking capacity of A9TPE4610?

6 kA Icn at 230 V AC per EN/IEC 60898-1, and 10 kA Icu at 230 V AC per EN/IEC 60947-2. There is also a 3 kA Icn1 rating under the same standards.

What standards does the A9TPE4610 comply with?

It complies with EN/IEC 60898-1 (MCB standard), EN/IEC 60947-2 (MCCB standard), and EN/IEC 62606 (arc fault detection device standard).

Where can I buy A9TPE4610 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
A9TPE4610