Skip to main content
Schneider Electric A9TPE4632 — 1-Pole MCB (DIN Rail)

Schneider Electric A9TPE4632 Acti9 iC40 ARC, 32 A C-Curve AF

MPNA9TPE4632
Active

Schneider Electric Acti9 iC40 ARC arc fault detection circuit breaker, A9TPE4632, 1P+N, 32 A, C-curve, 3000/6000 A Icn, 10 kA Icu, DIN rail mount.

$256.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9TPE4632 — Identification
ParameterValue
Product nameActi9 iC40 ARC
Product / component typeArc fault detection circuit breaker
Product rangeActi9
Device short nameiC40 ARC
Poles description1P + N
Number of protected poles1
A9TPE4632 — Electrical & Protection
ParameterValue
Rated current (In)32 A
Rated operational voltage (Ue)230 V AC 50 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9TPE4632 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal 1...10 mm² flexible Tunnel type terminal 1...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height91 mm
Depth73 mm
Tightening torque (by circuit)2 N.m
A9TPE4632 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
A9TPE4632 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1 EN/IEC 60947-2 EN/IEC 62606
A9TPE4632 — Electrical
ParameterValue
[Ui] rated insulation voltage250 V AC
[Uimp] rated impulse withstand voltage4 kV

Product details

Arc fault detection circuit breaker, 32 A, C-curve

The Schneider Electric A9TPE4632 is an Acti9 iC40 ARC arc fault detection circuit breaker (AFDD) — a 1P+N device rated 32 A with a C-curve magnetic trip of 5...10 x In. It combines thermal-magnetic overcurrent protection with series arc fault detection in a single 36 mm wide DIN-rail module, intended for outgoing circuits where series arcing (e.g. from a loose terminal or damaged cable) needs to be caught before it starts a fire. Breaking capacity is given under three standards: 3000 A Icn1 and 6000 A Icn per EN/IEC 60898-1, and 10 kA Icu per EN/IEC 60947-2 — all at 230 V AC 50 Hz. That means the part carries a domestic-grade Icn for MCB duty and a higher Icu for industrial backup protection; in a panel, the 10 kA Icu figure is the one to use for SCCR coordination with an upstream breaker.

Cable entry from top and bottom; tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible, with a 14 mm strip length and 2 N·m tightening torque. Tropicalisation severity B per IEC 60068-2-30 (28-day damp heat cycling) means it holds up in non-conditioned enclosures in humid environments — a detail that matters if this breaker lands in a coastal or unconditioned plant room.

Frequently asked questions

What breaking capacity does the A9TPE4632 have?

The A9TPE4632 has three rated breaking capacities: 3000 A Icn1 and 6000 A Icn per EN/IEC 60898-1, and 10 kA Icu per EN/IEC 60947-2, all at 230 V AC 50 Hz.

Where can I buy the A9TPE4632?

The A9TPE4632 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
A9TPE4632