Schneider Electric A9TPED625 Acti9 iC40N ARC, 25A, C-curve

MPN A9TPED625
Active

Schneider Electric Acti9 Active ARC iC40N, arc-fault detection device, 1P+N, 25 A, C curve, breaking capacity 3 kA (Icn1) / 6 kA (Icn) / 10 kA (Icu) at 230 V AC, 50 Hz.

$353.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TPED625 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50 Hz
Insulation voltage ui250 V AC
Breaking capacity3000 A Icn1 at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-25 °C
Storage temperature-40...80 °C
Pollution degree2

All specifications

A9TPED625 additional specifications
ParameterValue
ColorWhite (RAL 9003)
Depth73 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...40 °C

Product details

Arc-fault detection device for final circuits

Rated 25 A with a C curve, it detects series and parallel arcing faults that standard MCBs cannot sense — the magnetic tripping limit is set at 5 to 10 x In, and the thermal-magnetic trip unit handles overload and short-circuit protection per EN/IEC 60898-1 and EN/IEC 60947-2. Breaking capacity is rated at 3 kA (Icn1) and 6 kA (Icn) per EN/IEC 60898-1, plus 10 kA (Icu) per EN/IEC 60947-2, all at 230 V AC 50 Hz.

The C curve (magnetic trip 5–10 x In) means the device tolerates moderate inrush — suited for lighting, socket outlets, and small motor loads where starting current briefly exceeds the thermal threshold. The 25 A rating covers 2.5 mm² copper circuits up to roughly 5.7 kW at 230 V. The 1P+N format (neutral left, poles description: 1P+N) switches the phase and provides neutral disconnect — standard for single-phase final circuits in European distribution boards. The device is rated for outgoer position only (device location in system: Outgoer).