Skip to main content
Schneider Electric A9TYAE240

Schneider Electric A9TYAE240 Acti9 VigiARC iC60, 40 A, 30 mA

MPN A9TYAE240
Active

Schneider Electric Acti9 VigiARC iC60, active arc fault detection with residual current protection add-on block, 40 A, 30 mA, 2P, 230 V AC, DIN rail mount.

$395.87 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9TYAE240 specifications
ParameterValue
Voltage230 V AC
Insulation voltage ui400 V AC
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite (RAL 9003)
Depth73 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles > 25 A 20000 cycles <= 25 A
Mechanical life cycles20000 cycles
AccuracyVoltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Operating temperature-25...60 °C

Product details

It combines two protection functions in one DIN-rail module: series arc fault detection per EN/IEC 62606 and residual current protection per EN/IEC 61009-1 and EN/IEC 61009-2-1, with a rated current of 40 A and an earth-leakage sensitivity of 30 mA (Type A-SI, Super Immunised). The 30 mA sensitivity means it trips on ground faults that could harm personnel, while the Super Immunised designation prevents nuisance trips from high-frequency inverter noise or transient surges common on modern industrial lines. The overvoltage trip threshold is set at 275 V ±5 V, protecting downstream equipment from sustained voltage swells. Measurement accuracy is ±2 % for voltage and current, ±5 % for active power, which is sufficient for energy monitoring and fault logging via the compatible EcoStruxure Panel Server concentrators.

Clip-on mounting on DIN rail, occupying 2 x 9 mm pitches. Neutral is on the left. Operating altitude is rated to 2000 m; storage temperature range is -40 to 85 °C with tropicalisation severity B per IEC 60068-2-30 for 28 days, meaning it handles humidity cycling in non-condensing panel environments. Local signalling includes ON, OFF, and fault-trip LED indicators plus an arc fault diagnostic LED. Event management covers overvoltage, earth leakage, and overload events with date-and-time recording and maintenance indicators. This is an outgoer device — intended for final subcircuit protection, not incoming main switch duty.

MPN
A9TYAE240