Skip to main content
Schneider Electric A9TYBE240 — Residual Current Breakers (RCCB/RCBO)

Schneider A9TYBE240 Acti9 VigiARC iC40, 40A 30mA 2P Arc-Faul

MPNA9TYBE240
Active

Schneider Electric Acti9 Active VigiARC iC60 add-on block, 40 A, 30 mA earth leakage, 2P, 230 V AC, clip-on DIN rail.

$395.87Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9TYBE240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationON, OFF, fault trip LED arc fault diagnostic
A9TYBE240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230 V AC
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)250 V AC
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability10000 cycles > 25 A 20000 cycles <= 25 A
Mechanical durability (operating cycles)20000 cycles
A9TYBE240 — Identification
ParameterValue
Product nameActi9 Active VigiARC iC60
Product / component typeActive arc fault detection with residual current protection add-on block
Device short nameVigiARC iC60
A9TYBE240 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules2
Terminal connectionsTunnel type terminals1...10 mm² flexible Tunnel type terminals1...16 mm² rigid
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width54 mm
Height91 mm
Depth73 mm
A9TYBE240 — Environmental
ParameterValue
Operating ambient temperature-25...40 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating altitude2000 m
TropicalisationSeverity B conforming to IEC 60068-2-30 for 28 d
A9TYBE240 — Approvals
ParameterValue
StandardsEN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Schneider Electric A9TYBE240 is an Acti9 Active VigiARC iC60 add-on block that combines arc-fault detection with 30 mA residual current protection in a 2-pole, 40 A rated package, operating at 230 V AC / 50 Hz.

The 40 A rated current and 30 mA earth-leakage sensitivity are the two numbers that decide the BOM line: this block protects a final subcircuit (lighting, socket outlets, small loads) at 40 A, with Type A-SI (super-immunised) leakage detection that rejects nuisance trips from pulsed DC or high-frequency components — common on inverter-fed or LED circuits. Arc-fault detection per EN/IEC 62606 means the block distinguishes a dangerous series or parallel arc (loose connection, damaged cable) from normal switching transients and trips within the standard's time-current curve — critical for fire prevention in final circuits where conventional MCBs and RCDs alone cannot detect arcing. The 275 V ±5 V overvoltage trip threshold (phase-to-earth) protects against neutral loss or supply swells that could damage connected equipment, while the 250 V insulation rating and pollution degree 2 suit standard indoor panel environments.

Clip-on DIN-rail mount, 2-pole width (54 mm), neutral left. Tunnel terminals accept 1–10 mm² flexible or 1–16 mm² rigid; strip 14 mm, torque to 2 N·m. IP20 — panel interior only, no washdown. Electrical durability: 10,000 cycles above 25 A, 20,000 cycles at or below 25 A; mechanical durability 20,000 cycles. Tropicalisation Severity B per IEC 60068-2-30 for 28 days — rated for warm, humid environments without condensation inside the enclosure.

Frequently asked questions

Where can I buy A9TYBE240 and how do I get a price?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time.

What are the key ratings of A9TYBE240?

40 A rated current, 30 mA earth-leakage sensitivity (Type A-SI), 230 V AC / 50 Hz operating voltage, arc-fault detection per EN/IEC 62606, 2-pole, DIN-rail mount.

What compliance documentation does this part carry?

It is certified to EN/IEC 62606 (arc-fault detection devices), EN/IEC 61009-1 and EN/IEC 61009-2-1 (RCBOs), and carries the IMQ quality label. Tropicalisation Severity B per IEC 60068-2-30 is also listed.

What is the physical size of A9TYBE240?

Height 91 mm, width 54 mm (2-pole), depth 73 mm. Colour white (RAL 9003).

MPN