Specifications

A9V04240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9V04240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)130 V AC 50/60 Hz conforming to EN/IEC 61009-1 130 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Poles description2P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9V04240 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9V04240 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules4
Terminal connectionsTunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end
Wire stripping length14 mm for bottom connection
Terminal tightening torque3.5 N.m bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9V04240 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9V04240 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

Rated 40 A with 300 mA sensitivity, Type AC (sinusoidal AC fault currents only). Two-pole, instantaneous trip, no time delay.

Clip-on mount to DIN rail, 4 x 9 mm pitches wide (72 mm). Depth 73.5 mm, height 91 mm. Tightening torque 3.5 N.m. IP20 on the device body; IP40 inside a modular enclosure. Pollution degree 3 per IEC 60947-2.

Electrical ratings and standards

Rated operational voltage 130 V AC at 50/60 Hz per EN/IEC 61009-1 and 61009-2-1. Insulation voltage 500 V AC. Impulse withstand voltage 6 kV (Uimp). Withstands 8/20 µs impulse current of 250 A per IEC 61009-1. Voltage-independent tripping, so it operates without an external power supply.

Frequently asked questions

What is A9V04240 used for?

The A9V04240 is an add-on residual current device (RCD) that mounts to an Acti9 iC60 MCB to provide earth leakage protection for outgoing circuits. It is used in distribution panels for residential, commercial, and light industrial AC networks.

What are the key ratings of A9V04240?

40 A rated current, 300 mA earth leakage sensitivity, Type AC (sinusoidal AC only), 2 poles, instantaneous trip, voltage-independent operation, rated operational voltage 130 V AC.

Where can I buy A9V04240?

The A9V04240 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for A9V04240?

The A9V04240 complies with EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. It carries IP20 and IP40 (modular enclosure) ratings per IEC 60529, and pollution degree 3 per IEC 60947-2. Specific RoHS/REACH/UL documentation is available upon request through the distributor.

MPN